752
JD700B Series User’s Guide
instrument. Connecting an external power sensor is mandatory.
Figure 454 Directional power sensor connection
JD785B/JD786B/JD745B/JD746B
JD788B/JD748B
Selecting measurement mode
Procedure
1
Press the
MODE
hard key.
2
Select
More (1/2) > Power Meter > External RF Power Meter
.
Setting frequency
You need to set the frequency to be measured depending on your connected external power sensor.
Procedure
1
Press the
FREQ/DIST
hard key.
2
Press the
Frequency
soft key.
3
Enter a value by using the numeric keys. You can also use the rotary knob.
4
Select the unit:
GHz
,
MHz
,
kHz
, or
Hz
.
Setting amplitude
Procedure
1
Press the
AMP/SCALE
hard key.
2
Toggle the
Display
soft key and select the display method:
Relative
or
Absolute
.
3
If the
Relative
is selected, press the Set Reference soft key to set the current value as the
reference.
4
To specify the display range, complete the following steps:
Press the
Display Maximum
soft key to set the maximum value for the power meter.
Enter a value by using the numeric keys. You can also use the rotary knob.
Press the
dBm
soft key.
Press the
Display Minimum
soft key to set the minimum value for the power meter.
Enter a value by using the numeric keys. You can also use the rotary knob.
Press the
dBm
soft key.
Содержание CellAdvisor JD700B Series
Страница 2: ...CellAdvisorTM JD700B Series FW3 120 User s Guide ...
Страница 105: ...Chapter 4 Using Spectrum Analyzer 104 JD700B Series User s Guide Figure 44 PIM detection for multiple carriers ...
Страница 406: ...Chapter 11 Using EV DO Signal Analyzer JD700B Series User s Guide 405 3 Pilot 4 MAC 64 5 MAC 128 ...
Страница 734: ...Chapter 18 Perfroming BBU Emulation JD700B Series User s Guide 733 Figure 441 Example of verification of link status ...
Страница 763: ...Chapter 21 Performing Fiber Inspection 762 JD700B Series User s Guide Figure 461 Fiber inspection report ...
Страница 808: ...Appendix JD700B Series User s Guide 807 JD740B series ...
Страница 811: ...Appendix 810 JD700B Series User s Guide Figure 470 Append keywords window ...