Chapter 11
Using EV-DO Signal Analyzer
JD700B Series User’s Guide
415
Performing power statistics CCDF measurements
The Power Statistics Complementary Cumulative Distribution Function (CCDF) measurement characterizes
the power statistics of the input signal. It provides PAR (Peak to Average power Ratio) versus different
probabilities.
Setting measure setup
After configuring test parameters as described in the “Configuring test parameters” on page 389, you can
continue your measurement. The measurement settings can be saved and recalled as a file. You can also
use JDViewer, PC application software to configure a measure setup, save as a file, and load the file on to
the instrument.
Procedure
1
Press the
MEASURE SETUP
hot key.
2
Press the
CCDF Length
soft key to set the length of the CCDF.
3
Enter a value between 1 and 100 by using the numeric keys. You can also use the rotary knob.
4
Press the
Enter
soft key.
Measurement example
Figure 246 CCDF measurement with EV-DO signal analyzer
Conducting EV-DO OTA measurements
This Over The Air (OTA) measurement has channel scanner, PN scanner, multipath profile, and Code
Domain power screens. It is used to verify EV-DO transmitter performance at any location providing
reflective measurements and identifying signals providing from different sites. The Code Domain power
shows not only modulation performance metric but also amplifier capacity and code utilization metric. The
Amplifier capacity (code utilization) measurement is an estimate of the amount of power amplifier capacity
(code utilization) that is being used expressed in percent of maximum.
Содержание CellAdvisor JD700B Series
Страница 2: ...CellAdvisorTM JD700B Series FW3 120 User s Guide ...
Страница 105: ...Chapter 4 Using Spectrum Analyzer 104 JD700B Series User s Guide Figure 44 PIM detection for multiple carriers ...
Страница 406: ...Chapter 11 Using EV DO Signal Analyzer JD700B Series User s Guide 405 3 Pilot 4 MAC 64 5 MAC 128 ...
Страница 734: ...Chapter 18 Perfroming BBU Emulation JD700B Series User s Guide 733 Figure 441 Example of verification of link status ...
Страница 763: ...Chapter 21 Performing Fiber Inspection 762 JD700B Series User s Guide Figure 461 Fiber inspection report ...
Страница 808: ...Appendix JD700B Series User s Guide 807 JD740B series ...
Страница 811: ...Appendix 810 JD700B Series User s Guide Figure 470 Append keywords window ...