772
JD700B Series User’s Guide
Replaying EMF spectrum data
If you have recorded logging data in the EMF Spectrum mode, you can load the saved data in the EMF
Replayer mode and view them in the spectrogram chart for your analysis.
Loading a saved logging file
Procedure
1
In the EMF Analyzer mode, press the
MEASURE
hot key.
2
Press the
EMF Replayer
soft key.
The file explorer window appears.
3
Navigate to the
.grr
file that you have saved in the EMF Spectrum mode.
NOTE
In the File Information pane, you can find the properties of the file that you want to open.
If the selected logging data have been saved in a measurement mode other than EMF
Spectrum, the instrument will display an error message at the bottom of the window.
4
Press the
Load
soft key.
The EMF Replayer window appears with the upper spectrogram chart and the lower spectrum
chart. The spectrum chart displays two traces: isotropic trace and isotropic average trace.
Changing play options
Procedure
1
Press the
MEASURE
hot key.
2
Toggle the
Replay Direction
soft key between
FWD
and
REV
to change play direction to forward
or reverse.
3
Press the
Replay Speed
soft key, and then select the speed option:
x1
,
x2
,
x3
, and
x4
.
4
Press the
Play
soft key to start playing the recorded logging data.
5
Press the
Pause
soft key to pause or stop playing the recorded logging data.
6
To move to a particular failure position directly and play from there, complete the following steps:
Press the
Jump to Fail Index
soft key.
Enter a value by using the numeric keys.
Press the
Enter
soft key.
NOTE
If you connected a USB drive, do not remove it while playing. Doing so may freeze the
USB port, which will require you to restart the instrument to get a USB drive recognized
again.
Changing amplitude settings
You can change the reference level, scale per division, and units to optimize the display of the recorded data
while replaying, as you desire.
Procedure
1
Press the
AMP/SCALE
hard key.
2
To set the maximum reference level on the Y-axis, complete the following steps:
Press the
Reference Level
soft key.
Enter a value by using the numeric keys or the rotary knob with 10 dB increments.
Press your desired unit soft key from the choices, which vary depending on your selection
of the unit in the
Units
setting.
Содержание CellAdvisor JD700B Series
Страница 2: ...CellAdvisorTM JD700B Series FW3 120 User s Guide ...
Страница 105: ...Chapter 4 Using Spectrum Analyzer 104 JD700B Series User s Guide Figure 44 PIM detection for multiple carriers ...
Страница 406: ...Chapter 11 Using EV DO Signal Analyzer JD700B Series User s Guide 405 3 Pilot 4 MAC 64 5 MAC 128 ...
Страница 734: ...Chapter 18 Perfroming BBU Emulation JD700B Series User s Guide 733 Figure 441 Example of verification of link status ...
Страница 763: ...Chapter 21 Performing Fiber Inspection 762 JD700B Series User s Guide Figure 461 Fiber inspection report ...
Страница 808: ...Appendix JD700B Series User s Guide 807 JD740B series ...
Страница 811: ...Appendix 810 JD700B Series User s Guide Figure 470 Append keywords window ...