Chapter 2
Getting Started
50
JD700B Series User’s Guide
Procedure
1
Press the
SYSTEM
hot key.
2
Select
More (1/2) > Administration
, and then enter your password.
3
Toggle the
Edit Limit
soft key and select
Disable
to lock the
LIMIT
hot key or
Enable
to unlock
the key.
NOTE
Disabling the Edit Limit limits the access to the
LIMIT
hot key only. The Limit features
including displaying limit line(s) and Pass/Fail result function properly as predefined.
Running IP test
You can test an Internet Protocol (IP) configuration of the cell site’s backhaul.
Procedure
1
Press the
SYSTEM
hot key.
2
Select
More (1/2) > Utility > IP Test
.
3
Select the command option, from the following choices:
To display the route and measure transit delays of packets, toggle the
Commands
soft key
and select
Traceroute
.
To display the reachability and measure the round-trip time, toggle the
Commands
soft key
and select
Ping
.
4
To set the destination IP address to be tested, complete the following steps:
Press the
Destination IP
soft key.
Press the
First Octal
soft key.
Enter a value, and then press the
Enter
soft key.
Press the
Second Octal
soft key and repeat step
c
.
Press the
Third Octal
soft key and repeat step
c
.
Press the
Fourth Octal
soft key and repeat step
c
.
5
Press the
Execute
soft key and select
Start
to start testing.
Test result is displayed on the screen as the test is progressing.
6
Press the
Execute
soft key and select
Stop
to stop testing.
7
Optional
. Press the
Save
soft key to save the test result as a
.txt
file type.
Activating StrataSync
StrataSync is a cloud-based solution that provides asset, configuration, and test data management for
VIAVI instruments. StrataSync manages and tracks test instruments, collects and analyzes results from the
entire network, and informs and trains the workforce.
The JD700B series is compatible with the VIAVI StrataSync cloud. This optional capability allows you to
manage your instrument inventory ensuring you know where all your valuable equipment is and which
engineer is using it. In addition, it allows you to keep your instruments current through the remote upgrade
capability that ensures all instruments have the latest firmware. It also enables the centralized distribution
of configuration settings to ensure all your engineers use the same instrument settings resulting in
consistent measurements.
Once testing is completed, the trace files can be uploaded onto StrataSync for secure storage and sharing.
Содержание CellAdvisor JD700B Series
Страница 2: ...CellAdvisorTM JD700B Series FW3 120 User s Guide ...
Страница 105: ...Chapter 4 Using Spectrum Analyzer 104 JD700B Series User s Guide Figure 44 PIM detection for multiple carriers ...
Страница 406: ...Chapter 11 Using EV DO Signal Analyzer JD700B Series User s Guide 405 3 Pilot 4 MAC 64 5 MAC 128 ...
Страница 734: ...Chapter 18 Perfroming BBU Emulation JD700B Series User s Guide 733 Figure 441 Example of verification of link status ...
Страница 763: ...Chapter 21 Performing Fiber Inspection 762 JD700B Series User s Guide Figure 461 Fiber inspection report ...
Страница 808: ...Appendix JD700B Series User s Guide 807 JD740B series ...
Страница 811: ...Appendix 810 JD700B Series User s Guide Figure 470 Append keywords window ...