Chapter 15
Using Cable and Antenna Analyzer
JD700B Series User’s Guide
537
NOTE
See “Performing reflection measurements” for more information on how to set other
measurement setup parameters for the Cable Loss (1 Port) measurement.
Measurement example
Figure 327 Cable loss (1 port) measurement
NOTE
You can use the
LIMIT
hot key to analyze your measurements with the user-definable
limit and Pass/Fail indication. See “Setting limit for cable and antenna analyzer” on page
544 for more information.
Figure 328 Cable loss (1 port) measurement with the zone enabled
NOTE
You can go to
MEASURE SETUP > Zoom
to view your measurements in detail with the
user-definable zoom zones. See “Setting zoom zones” on page 543 for more information.