Chapter 7
Using WCDMA/HSPA+ Signal Analyzer
190
JD700B Series User’s Guide
NOTE
You can use the
LIMIT
hot key to analyze your measurements with the user-definable
limit and Pass/Fail indication. See “Setting limit for modulation tests” on page 197 for
more information.
Setting display
You can view your measurement results in a different view option.
Procedure
1
Press the
TRACE/DISPLAY
hard key.
2
Toggle the
View
soft key and select the display option:
Zoom:
You can view the result in detail with zoom-in window.
The Position and Width menus become activated.
Full:
You can view the full measurement result.
3
To define the zoom start position and width, complete the following steps:
Press the
Position
soft key.
Enter a value of the position by using the numeric keys.
Press the
Enter
soft key.
Press the
Width
soft key, and then select the Walsh code option:
32
,
64
,
128
, or
256
.
4
Toggle the
Constellation
soft key between
On
and
Off
to enable or disable the constellation
chart on the Code Domain Power screen.
5
Toggle the
Control Channel
soft key and select the control channel mode option:
Normal:
You can view the relative ratio of each control channel vs. total power.
Delta:
You can view the relative ratio of each control channel vs. CPICH channel.
Relative code domain power
The Relative Code Domain Error (RCDE) measurement provides relative code domain error analysis that is
particularly required by HSPA+.
Setting measure setup
After configuring test parameters as described in the “Configuring test parameters” on page 173, you can
continue your measurement. The measurement settings can be saved and recalled as a file. You can also
use JDViewer, PC application software to configure a measure setup, save as a file, and load the file on to
the instrument.
Procedure
1
Press the
MEASURE SETUP
hot key.
2
Optional
. To set the scramble code, complete the following steps:
Toggle the
Scramble
soft key between
Auto
and
Manual
.
Enter a value by using the numeric keys to set manually.
Press the
Enter
soft key.
3
Optional
. Press the
Detect Mode
soft key, and then select the signal standard option:
WCDMA
,
HSDPA
, or
HSPA+
. HSDPA is set by default.
NOTE
It is recommended that you select
HSPA+
for RCDE testing.
4
To set the S-CCPCH information of the system to be tested, complete the following steps:
Press the
S-CCPCH
soft key.
Toggle the
S-CCPCH
soft key between
On
and
Off
to enable or disable the S-CCPCH.
Содержание CellAdvisor JD700B Series
Страница 2: ...CellAdvisorTM JD700B Series FW3 120 User s Guide ...
Страница 105: ...Chapter 4 Using Spectrum Analyzer 104 JD700B Series User s Guide Figure 44 PIM detection for multiple carriers ...
Страница 406: ...Chapter 11 Using EV DO Signal Analyzer JD700B Series User s Guide 405 3 Pilot 4 MAC 64 5 MAC 128 ...
Страница 734: ...Chapter 18 Perfroming BBU Emulation JD700B Series User s Guide 733 Figure 441 Example of verification of link status ...
Страница 763: ...Chapter 21 Performing Fiber Inspection 762 JD700B Series User s Guide Figure 461 Fiber inspection report ...
Страница 808: ...Appendix JD700B Series User s Guide 807 JD740B series ...