A Appendix
400
7UM61 Manual
C53000-G1176-C127-3
5148
Phase Rotation L1L3L2 (Rotation
L1L3L2)
P.System Data 1
AM
ON
OFF
*
*
LED
BO
70
129
1
Yes
5151
I2 switched OFF (I2 OFF)
Unbalance Load
AM
ON
OFF
*
*
LED
BO
70
131
1
Yes
5152
I2 is BLOCKED (I2 BLOCKED)
Unbalance Load
AM
ON
OFF
ON
OFF
*
LED
BO
70
132
1
Yes
5153
I2 is ACTIVE (I2 ACTIVE)
Unbalance Load
AM
ON
OFF
*
*
LED
BO
70
133
1
Yes
5156
Unbalanced load: Current
warning stage (I2> Warn)
Unbalance Load
AM
ON
OFF
*
*
LED
BO
70
134
1
Yes
5158
Reset memory of thermal replica
I2 (RM th.rep. I2)
Unbalance Load
AM
ON
OFF
*
*
LED
BO
70
137
1
Yes
5159
I2>> picked up (I2>> picked up)
Unbalance Load
AM
*
ON
OFF
*
LED
BO
70
138
2
Yes
5160
Unbalanced load: TRIP of current
stage (I2>> TRIP)
Unbalance Load
AM
*
ON
m
LED
BO
70
139
2
Yes
5161
Unbalanced load: TRIP of
thermal stage (I2
Θ
TRIP)
Unbalance Load
AM
*
ON
m
LED
BO
70
140
2
Yes
5165
I2> picked up (I2> picked up)
Unbalance Load
AM
*
ON
OFF
*
LED
BO
70
150
2
Yes
5173
>BLOCK stator earth fault protec-
tion (>S/E/F BLOCK)
Stator E Fault
EM
*
*
*
LED BI
BO
5176
>Switch off earth current de-
tec.(S/E/F) (>S/E/F Iee off)
Stator E Fault
EM
ON
OFF
*
*
LED BI
BO
70
152
1
Yes
5181
Stator earth fault prot. is switch
OFF (S/E/F OFF)
Stator E Fault
AM
ON
OFF
*
*
LED
BO
70
156
1
Yes
5182
Stator earth fault protection is
BLOCK. (S/E/F BLOCKED)
Stator E Fault
AM
ON
OFF
ON
OFF
*
LED
BO
70
157
1
Yes
5183
Stator earth fault protection is
ACTIVE (S/E/F ACTIVE)
Stator E Fault
AM
ON
OFF
*
*
LED
BO
70
158
1
Yes
5186
Stator earth fault: U0 picked up
(U0> picked up)
Stator E Fault
AM
*
ON
OFF
*
LED
BO
70
159
2
Yes
5187
Stator earth fault: U0 stage TRIP
(U0> TRIP)
Stator E Fault
AM
*
ON
m
LED
BO
70
160
2
Yes
5188
Stator earth fault: I0 picked up
(3I0> picked up)
Stator E Fault
AM
*
ON
OFF
*
LED
BO
70
168
2
Yes
5189
Earth fault in phase L1 (Uearth
L1)
Stator E Fault
AM
*
ON
OFF
*
LED
BO
70
169
2
Yes
5190
Earth fault in phase L2 (Uearth
L2)
Stator E Fault
AM
*
ON
OFF
*
LED
BO
70
170
2
Yes
5191
Earth fault in phase L3 (Uearth
L3)
Stator E Fault
AM
*
ON
OFF
*
LED
BO
70
171
2
Yes
5193
Stator earth fault protection TRIP
(S/E/F TRIP)
Stator E Fault
AM
*
ON
m
LED
BO
70
173
2
Yes
5194
Stator earth fault: direction
forward (SEF Dir Forward)
Stator E Fault
AM
ON
OFF
*
*
LED
BO
70
174
1
Yes
5203
>BLOCK frequency protection
(>BLOCK Freq.)
Frequency Prot.
EM
*
*
*
LED BI
BO
5206
>BLOCK stage f1 (>BLOCK f1)
Frequency Prot.
EM
ON
OFF
*
*
LED BI
BO
70
177
1
Yes
5207
>BLOCK stage f2 (>BLOCK f2)
Frequency Prot.
EM
ON
OFF
*
*
LED BI
BO
70
178
1
Yes
5208
>BLOCK stage f3 (>BLOCK f3)
Frequency Prot.
EM
ON
OFF
*
*
LED BI
BO
70
179
1
Yes
5209
>BLOCK stage f4 (>BLOCK f4)
Frequency Prot.
EM
ON
OFF
*
*
LED BI
BO
70
180
1
Yes
No.
Description
Function
Type
of In-
for-
matio
n
Log Buffers
Configurable in Matrix
IEC 60870-5-103
E
ven
t Lo
g
O
N
/O
F
F
Tr
ip
(F
au
lt)
L
o
g
ON/O
F
F
G
rou
nd F
a
u
lt Lo
g O
N
/O
F
F
Ma
rk
ed
in
Os
cill.
Rec
o
rd
LED
B
ina
ry
Inpu
t
Fu
nc
ti
o
n
K
e
y
Re
la
y
C
h
at
ter
S
u
pp
ress
ion
Ty
p
e
In
fo
rma
ti
o
n
N
u
m
b
er
Da
ta
Un
it
Gen
er
al In
te
rr
o
g
ati
o
n
www
. ElectricalPartManuals
. com
Содержание Siprotec 7UM611
Страница 16: ...Contents 16 7UM61 Manual C53000 G1176 C127 3 w w w E l e c t r i c a l P a r t M a n u a l s c o m ...
Страница 232: ...2 Functions 232 7UM61 Manual C53000 G1176 C127 3 w w w E l e c t r i c a l P a r t M a n u a l s c o m ...
Страница 292: ...3 Mounting and Commissioning 292 7UM61 Manual C53000 G1176 C127 3 w w w E l e c t r i c a l P a r t M a n u a l s c o m ...
Страница 410: ...A Appendix 410 7UM61 Manual C53000 G1176 C127 3 w w w E l e c t r i c a l P a r t M a n u a l s c o m ...
Страница 412: ...Literature 412 7UM61 Manual C53000 G1176 C127 3 w w w E l e c t r i c a l P a r t M a n u a l s c o m ...