Operating Instructions for SR131 and SR231 Safety Monitoring Relays
S11
A1
S12 S13
23
K1/K2
TYPE
SR131
A1/A2
Fuse
A1
2
S11
A1
S12 S1
3 23
A2
S21
K1/K2
TYPE
SR231
A1/A2
Fuse
Y1 Y2
13
34
14
PE
24
Y1 Y2
13
14
Y34
S22
Y44
K1
K2
13 23
14 24
A1
Y34
Y44
Y43
A1
Y44
24
S23
R
R
K1
K2
13 23
14 24
A1
Y34
A1
Y44
Dimensions / Encombrements / Maße
Terminal marking/ Repérage des bomes /Klemmenanzeiger
1/8
10/2003
Safety module for a total of 2 magnetic switches with a
normally open and a normally closed contact each
according to EN 60947-5-3
Module de sécurité pour au total 2 interrupteurs
magnétiques comportant chacun un contact à
fermeture et un contact à ouverture
selon EN 60947-5-3
Sicherheitsbaustein für insgesamt 2 Magnetschalter mit
jeweils einem Schließer- und einem Öffnerkontakt
gemäß EN 60947-5-3
SR131....
SR231...
SR131...
SR231...
SR231...
SR131...
S11
A1
S12
Y1
S13
Y2
23
13
A2
S21
Y34
S22
Y44
S23 24
14
A1
S11
Y2
S12
Y4
S13
13
23
S21
A2
S22
Y34
S23
Y44
24
14
22.5 mm
(0.89 in)
114 mm
(4.48 in)
99 mm
(3.89 in)
22.5 mm
(0.89 in)
114 mm
(4.48 in)
99 mm
(3.89 in)
SR231...
Application
Safety systems are comprised of many components. No one safety
component will insure the safety of the system. The design of the complete
safety system should be considered before you begin. It is very important to
follow applicable safety standards when installing and wiring these
components.
The unit SR131/SR231 is a safety module for monitoring of magnetic
switches with a normally closed and a normally open contact each.
The unit is suitable for the following applications up to control category 4
in accordance with EN 954:
• Safety door locks with magnetic switches.
• Monitoring of several doors with one module.
The module provides two potential free safety contacts and two solid-state
signal outputs. In case of a direct use in a category 4 cut-off circuit the two
safety contacts 13-14 and 23-24 must be connected in series. The contact
multiplication by means of contactors with guided contacts is shown in the
wiring diagram.
Due to the redundant design of the unit the occurrence of a single fault does
not lead to the loss of the safety function. All detected faults are displayed
through the solid-state signal output Y34.
After connecting the supply voltage to the terminals A1-A2, the module runs
an internal test. During this test, all LEDs in the panel in the device cover
are illuminated for 2 seconds and the transistor outputs Y34 / Y44 are
activated in this time.
If all connected magnetic switches are actuated and the starting circuit
Y1-Y2 is closed, the safety outputs are activated. The contact change
between normally closed and normally open of a magnetic switch must
occur within a period of 0.5 seconds. An unused input (e.g. S21-S23) must
be jumpered.
It is imperative that an external fuse be connected as shown on the
"WIRING DIAGRAM FOR MODULE SR131/SR231 SAFETY RELAY".
For maximum protection of the outputs, please refer to "TECHNICAL
DATA".
Safety
Technology
& Innovation