XPS-DMB

R

Operating Instructions for SR131 and SR231 Safety Monitoring Relays

XPS-DMB

K1

K2

0V

S21

S22

S23

Y34

Y44

14

24

23

13

Y2

Y1

S13

S12

S11

S3

K3

K4

ESC

S1

XCS-DM_

WH

BK

BU

BN+

S2

XCS-DM_

BK

WH

BN+

BU

K3

K4

Power A1/A2
Fault
K1/K2

Fault

K1/K2

DC

DC

A1

A2

K3

K4

K3

K4

3/8

10/2003

!

 DANGER

HAZARDOUS VOLTAGE

• Disconnect all power before working on equipment.

Electric shock will result in death or serious injury.

S1.1

XCS-DM_

WH

BK

BU

BN+

S1.2

XCS-DM_

WH

BK

BU

BN+

S1.3

XCS-DM_

WH

BK

BU

BN+

S11

S21

S12

S22

S13

S23

S21

S22

S23

Unused inputs must be jumpered.
For example:
Il faut ponter les entrées qui ne servent pas.
Par example:
Nicht benutzte Eingänge müssen gebrückt
werden.
Zum Beispiel:

Common connection of several magnetic switches.
Category 3
Branchement conjoint de interrupteurs magnétiques.
Catégorie 3
Gemeinsamer Anschluß mehrerer Magnetschalter.
Kategorie 3

for / pour / für

S2.1 ... S2.3

2 Transistor outputs
2 Sorties statiques
2 Transistorausgänge

(1) =

2 Safety outputs
2 Sorties de sécurité
2 Sicherheitsausgänge

(2) =

See Technical Data for maximum
fuse sizes (page 7/8)
Voir caractéristiques techniques
pour le calibre maximal des
fusibles (page 7/8).
Siehe technische Daten für max.
Sicherung (Seite 7/8).

(3) =

23

24

13

14

K1

K2

M

L

N

F

(3)

Enabling circuit

Circuits électriques

d'autorisation

Freigabestromkreise

(2)

(1)

Protective guard 1, closed

Protecteur 1, fermé

Schutzgitter 1, geschlossen

Protective guard 2, closed

Protecteur 2, fermé

Schutzgitter 2, geschlossen

to PLC

vers API

zur SPS

LOGIC

F1
(3)

Start Button
Bouton marche
Starttaste

S3 =

External Start conditions
Conditions de démarrage externes
Externe Start Bedingungen

ESC =

Maximum number of magnetic switches
Nombre maximum d´interrupteurs magnétiques
Maximale Anzahl der Magnetschalter

XCS-DM_

WH

BK

BU

BN+

XCS-DM_

WH

BK

BU

BN+

S11 S12 S13

6

3

S21 S22 S23

6

3

Wiring diagram for SR131/231
Schéma de raccordement pour SR131/231
Anschlußplan für SR131/231

SR231

Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]

Содержание SR131A

Страница 1: ...hes with a normally closed and a normally open contact each The unit is suitable for the following applications up to control category 4 in accordance with EN 954 Safety door locks with magnetic switc...

Страница 2: ...jusque dans la cat gorie de commande 4 selon EN 954 Verrouillage de portes de protection par interrupteurs magn tiques Surveillance de plusieurs portes de protection avec un m me module Ce module comp...

Страница 3: ...2 Transistor outputs 2 Sorties statiques 2 Transistorausg nge 1 2 Safety outputs 2 Sorties de s curit 2 Sicherheitsausg nge 2 See Technical Data for maximum fuse sizes page 7 8 Voir caract ristiques t...

Страница 4: ...couvercle du bo tier Systemdiagnose mittels LED Anzeige im Geh usedeckel LED2 Fault Type of fault Cause of fault Action DEL2 Fault Type de d faut Cause du d faut Action LED2 Fault Fehlerart Fehlerurs...

Страница 5: ...n s i o n d a l i m e n t a t i o n A u t o t e s t a c h e v S u p p l y O n S e l f t e s t i n g f i n i s h e d S p a n n u n g E i n S e l b s t t e s t b e e n d e t I n t e r r u p t e u r m a...

Страница 6: ...26 20 AWG Stranded with cable end without plastic sleeve 0 25 1 mm2 24 18 AWG Stranded with TWIN cable end with plastic sleeve 0 5 1 5 mm2 22 14 AWG SR231 Single wire connection Without cable end soli...

Страница 7: ...fety outputs 13 14 23 24 Transistor outputs closing function solid state A1 Y34 A1 Y44 max 20 mA Maximum switching capacity of outputs AC 15 C300 1800VA 180VA DC 13 24V 1 5A L R 50ms The sum of simult...

Страница 8: ...C Programmable Controllers PLC Operator interfaces HMI Distributed I O Software Drives Motion Controls Servo AC Drives Motion Controllers Encoders Temperature Process Controllers Single and Multi loop...

Отзывы: