Chapter 6: Using the Web Interface
220
Event/Context
Default Assertion Message when
the Event = TRUE
Default Assertion Message
when the Event = FALSE*
Peripheral Device Slot > * >
Numeric Sensor > Below lower
warning
Peripheral device
'[EXTSENSORNAME]' in slot
'[EXTSENSORSLOT]' asserted 'below
lower warning' at [READING].
Peripheral device
'[EXTSENSORNAME]' in slot
'[EXTSENSORSLOT]' deasserted
'below lower warning' at
[READING].
Peripheral Device Slot > * >
Numeric Sensor > Below lower
critical
Peripheral device
'[EXTSENSORNAME]' in slot
'[EXTSENSORSLOT]' asserted 'below
lower critical' at [READING].
Peripheral device
'[EXTSENSORNAME]' in slot
'[EXTSENSORSLOT]' deasserted
'below lower critical' at
[READING].
Peripheral Device Slot > * >
State Sensor > Unavailable
Peripheral device
'[EXTSENSORNAME]' in slot
'[EXTSENSORSLOT]' unavailable.
Peripheral device
'[EXTSENSORNAME]' in slot
'[EXTSENSORSLOT]' available.
Peripheral Device Slot > * >
State Sensor > Alarmed / Open
/ On
Peripheral device
'[EXTSENSORNAME]' in slot
[EXTSENSORSLOT] is
[SENSORSTATENAME].
Peripheral device
'[EXTSENSORNAME]' in slot
[EXTSENSORSLOT] is
[SENSORSTATENAME].
Modem > Dial-in link
established
An incoming call from caller
'[CALLERID]' was received.
The incoming call from caller
'[CALLERID]' was disconnected:
[CALLENDREASON].
Modem > Modem attached
A [MODEMTYPE] modem was
attached.
Modem > Modem detached
A [MODEMTYPE] modem was
removed.
Power Logic Device > * >
Connected
PowerLogic Device has been
connected to [PORTTYPE] port
[PORTID].
PowerLogic Device has been
disconnected from [PORTTYPE]
port [PORTID].
Power Logic Device > * > Alarm PowerLogic Device connected to
[PORTTYPE] port [PORTID] entered
an alarm condition.
PowerLogic Device connected to
[PORTTYPE] port [PORTID] left
an alarm condition.
Power Logic Device > * >
Sensor > * > Unavailable
Sensor '[PLSENSORNAME]' on Power
Logic Device at [PORTTYPE] port
'[PORTID]' unavailable.
Sensor '[PLSENSORNAME]' on
Power Logic Device at
[PORTTYPE] port '[PORTID]'
available.
Power Logic Device > * >
Sensor > * > Above upper
critical
Sensor '[PLSENSORNAME]' on Power
Logic Device at [PORTTYPE] port
'[PORTID]' asserted 'above upper
critical' at [SENSORREADING]
[SENSORREADINGUNIT].
Sensor '[PLSENSORNAME]' on
Power Logic Device at
[PORTTYPE] port '[PORTID]'
deasserted 'above upper critical'
at [SENSORREADING]
[SENSORREADINGUNIT].
Содержание EMX2-888
Страница 19: ...Chapter 1 Introduction 5 Retrieval of the link local IPv4 address See IPv4 Address on page 72...
Страница 71: ...Chapter 4 Connecting External Equipment Optional 57...
Страница 148: ...Chapter 6 Using the Web Interface 134 LHX 20 SHX 30 LHX 40 PowerLogic PM710...
Страница 506: ...Appendix F LDAP Configuration Illustration 492 5 Click OK The EMX_Admin role is created 6 Click Close to quit the dialog...
Страница 526: ...Appendix H RADIUS Configuration Illustration 512 Note If your EMX uses PAP then select PAP...
Страница 527: ...Appendix H RADIUS Configuration Illustration 513 10 Select Standard to the left of the dialog and then click Add...
Страница 528: ...Appendix H RADIUS Configuration Illustration 514 11 Select Filter Id from the list of attributes and click Add...
Страница 531: ...Appendix H RADIUS Configuration Illustration 517 14 The new attribute is added Click OK...
Страница 532: ...Appendix H RADIUS Configuration Illustration 518 15 Click Next to continue...