[SENSe:]POWer:ACHannel:FILTer:ALPHa:CHANnel<channel>
<Alpha>
This command defines the roll-off factor for the weighting filter of the specified TX
channel.
Suffix:
<channel>
.
1...11
the TX channel
Parameters:
<Alpha>
<numeric value>
*RST:
0,22
Example:
POW:ACH:FILT:ALPH:CHAN3 0,35
Sets the alpha value for the weighting filter for the TX channel 3
to 0,35.
Manual operation:
See
[SENSe:]POWer:ACHannel:FILTer[:STATe]:ACHannel
<State>
This command activates the weighting filter for the adjacent channel.
Parameters:
<State>
ON | OFF
*RST:
OFF
Example:
POW:ACH:FILT:ACH ON
Manual operation:
See
[SENSe:]POWer:ACHannel:FILTer[:STATe]:ALTernate<channel>
<State>
This command activates the weighting filter for the specified alternate channel.
Suffix:
<channel>
.
1...11
the alternate adjacent channel
Parameters:
<State>
ON | OFF
*RST:
OFF
Example:
POW:ACH:FILT:ALT3 ON
Activates the weighting filter for alternate channel 3.
Manual operation:
See
[SENSe:]POWer:ACHannel:FILTer[:STATe]:CHANnel<channel>
<State>
This command activates the weighting filter for the specified TX channel.