CALCulate<n>:MARKer<m>:FUNCtion:POWer:RESult:PHZ
.............................................. 746
.................................................................................. 746
............................................................................................... 747
........................................................................................ 747
CALCulate<n>:MARKer<m>:FUNCtion:POWer:RESult:PHZ
<State>
This command switches the query response of the power measurement results
between output of absolute values and output referred to the measurement bandwith.
The measurement results are output with the
command.
Suffix:
<n>
.
Selects the measurement window.
<m>
Selects the marker.
Parameters:
<State>
ON | OFF
ON
Results output: channel power density in dBm/Hz
OFF
Results output: channel power is displayed in dBm
*RST:
OFF
Example:
CALC:MARK:FUNC:POW:RES:PHZ ON
Output of results referred to the channel bandwidth.
For details on a complete measurement example refer to
CALCulate<n>:MARKer<m>:FUNCtion:POWer:RESult?
Manual operation:
See
[SENSe:]POWer:ACHannel:MODE
<Mode>
This command switches between absolute and relative adjacent channel measure-
ment. The command is only available with span > 0 and if the number of adjacent
channels is greater than 0.
For the relative measurement the reference value is set to the currently measured
channel power using the command
[SENSe:]POWer:ACHannel:REFerence:
.
Parameters:
<Mode>
ABSolute | RELative
ABSolute
absolute adjacent channel measurement
RELative
relative adjacent channel measurement
*RST:
RELative