Remote Control
R&S
®
ESR
783
User Manual 1175.7068.02 ─ 12
<m>
1...16
marker
<k>
1...8
limit line
Return values:
<Condition>
0
The marker has passed the limit check.
1
The marker is inside the margins of a limit line.
2
The marker has failed the limit check.
Example:
CALC:MARK1:FUNC:FME:LIM2:COND?
Queries the condition of marker 1 in relation to limit line 2.
Usage:
Query only
Manual operation:
See
CALCulate<n>:MARKer<m>:FUNCtion:FMEasurement:LIMit<k>:DELTa?
<Amplitude>
This command queries the vertical distance from the marker position to the limit line.
The unit is dB.
If the marker has been assigned to a different trace than the limit line, the command
returns -200.
Suffix:
<n>
.
irrelevant
<m>
1...16
marker
<k>
1...8
limit line
Return values:
<Amplitude>
Vertical distance to the limit line in dB.
Example:
CALC:MARK3:FUNC:FME:LIM2:DELT?
Queries the distance of marker 3 to the second limit line.
Usage:
Query only
Manual operation:
See
CALCulate<n>:MARKer<m>:FUNCtion:FMEasurement:RESult?
<Result>
This command queries the result of the EMI measurement at the marker position.
Suffix:
<n>
.
irrelevant
Remote Commands in Spectrum Analyzer Mode