Remote Control
R&S
®
ESR
911
User Manual 1175.7068.02 ─ 12
Manual operation:
See
"Generator Frequency (Numerator/Denominator/Offset)"
SOURce<n>:EXTernal<generator>:FREQuency:SWEep[:STATe]
<State>
This command activates or deactivates the frequency sweep for the selected genera-
tor.
This command is requires the optional External Tracking Generator.
Suffix:
<n>
.
irrelevant
<generator>
1 | 2
external generator
Parameters:
<State>
ON | OFF
*RST:
OFF
Example:
SOUR:EXT1:FREQ:SWE ON
Activates the frequency sweep for external generator 1.
SOURce<n>:EXTernal<generator>:POWer[:LEVel]
<Level>
This command sets the output power of the selected generator.
This command is only valid for the External Tracking Generator option (R&S
FSV-B10).
Suffix:
<n>
.
irrelevant
<generator>
1 | 2
tracking generator
For Noise Figure measurements (K30): 1 only
Parameters:
<Level>
<numeric value>
*RST:
-20 dBm
Example:
SOUR:EXT:POW -30dBm
Sets the generator level to -30 dBm
Mode:
A, NF
Manual operation:
See
SOURce<n>:EXTernal<generator>:ROSCillator[:SOURce]
<Source>
This command controls selection of the reference oscillator for the external tracking
generator (requires option R&S
FSV-B10).
If the external reference oscillator is selected, the reference signal must be connected
to the rear panel of the instrument.
Remote Commands to Control the Tracking Generator