Note:
This command would normally be used when resuming playback of a Show
Playlist that had been paused due to a fire alarm event.
Script Automation TPC Lamp On
– this command is used to instruct the Digital Cinema
projector to turn
ON
(strike) its lamp in preparation for resuming playback.
Script Automation TPC Lamp Off
– this command is used to instruct the Digital Cinema
projector to turn
OFF
its lamp as a safety precaution during a fire alarm event.
Script Automation GPI <channel> <On|Off|Pulse>
- this command is used to send a GPI
Output
signal to external automation devices.
Examples:
Script Automation GPI 7 On
Script Automation GPI 3 Off
Script Automation GPI 4 Pulse 12
Script Automation CP650 <operation>
- this command, along with operation details, is used to
interface with an external CP650 audio processor. All of the Show Playlist (or script) CP650
commands are supported although only a couple of examples is provided.
Examples:
Script Automation CP650 Fader 5.5
Script Automation CP650 Format NS
Script Automation CP650 FadeTo 8.5 Over 24
Script Automation CP650 Mute On
Script Automation CP650 Mute Off
WAIT <ms>
- this command is used to insert a delay (in milliseconds) before processing the next
command.
Example – wait 2 seconds:
Wait
2000
Log Add Oper <”message”>
- this command is used to manually add a log entry to the
“Operations” log to indicate the external alarm processing.
Example:
Log Add Oper “Fire Alarm input detected – Emergency procedure invoked”
Example GPI Batch File
Script transport pause
Script automation tpc douser close
Script automation cp650 format NS
Script automation gpi 7 on
Wait 2000
Script automation gpi 8 pulse 12
Log add oper “Fire alarm input detected – Emergency procedure invoked”
QuVIS Acuity
™
Page 120