How triggered record works
1.
From the
Record Advanced
menu page the start and stop (optional) trigger methods must first be defined using
the “”Auto-record start trigger” and “Auto-record stop trigger” controls. Secondly, the values that correspond to the
start and stop triggers must be defined using the “Start recording at” and “Stop recording at” controls.
2.
Ensure that all of the record settings are set according to your project parameters.
3.
Press the
REC
button (directly above the Jog/Shuttle wheel) to load the record settings. You can verify that the
system is in a “Record Ready” by looking on the dashboard. If the VTR status window displays [RECORD] the
system is currently in record mode (vmode r).
4.
To arm the system to record and wait for the Record start trigger event, press the
REC+PLAY
buttons together.
When the start trigger point is reached, record will begin. If a stop trigger has been set, record will stop once the
end trigger value has occurred.
To cancel the armed-and-waiting process, press the
STOP
transport button the front of the Acuity, which will cancel
the process and clear the trigger events. As indicated, if the operation is canceled, the trigger events will be cleared
and must be reset manually if triggered playback is desired.