4-4
■
Recommended Interface
4.1.3 Pin Arrangement
Connector:
R03-R8F
Applicable connector:
R03-PB8M (Tajimi Electronics)
Common
or
10 k
Ω
+30V or less
External device
TS-3200A output
Load voltage
Load current
100mA or less
ON resistance
10
Ω
or less
OFF resistance 500k
Ω
or higher
30VDC or less
RL
+5 V
RL
A
CLR IN
B
TRIG IN
C
CCW/CCW selection
D
Input common
E
READY OUT
F
COM for the above
Input
Output
G
TRIG OUT
H
COM for the above
Pin arrangement