3-17
■
AUTO (automatic) Setting
(4)
Select MODE.
The default value is 1: AUTO. Press the [ENTER] key.
When you press the [ENTER] key, the torque zero compensation value is determined automatically.
■
MANU (manual operation) Setting
(5)
1
Select MODE.
Select 2:MANU using the
and
keys and then press the [ENTER] key.
Press the [ENTER] key to move the cursor to
2
.
The default value is 1: AUTO. Therefore, if you select 2:MANU, exit the torque zero setting screen, then
enter the same screen again, 1: AUTO is selected.
2
CW ZERO/CCW ZERO
Numeric values have already been set to CW ZERO and CCW ZERO.
The torque value currently displayed in the measurement display (with the decimal point removed) is
added.
Example:
Current setting:
4000
LCD display value:
-10.04
Torque zero value = 4000+(-1004) = 2996
Press the [ENTER] key.
■
Clear Function
(5)
Select MODE.
Select 3: CLR using the
and
keys and then press the [ENTER] key.
When you press the [ENTER] key, the zero value for the rotational direction currently selected becomes
the default value.
3. Basic Operations
Содержание TS-3200A
Страница 1: ...TS 3200A DIGITAL TORQUE METER INSTRUCTION MANUAL ONO SOKKI CO LTD...
Страница 21: ...Chapter 2 Before Use 2 1 Name and Function of Each Section 2 2 Detector Connections...
Страница 96: ...4 30...
Страница 143: ...6 1 Chapter 6 Menus 6 1 MENU Key 6 2 CAL Key 6 3 TRQ ZERO Key...
Страница 150: ...6 8...
Страница 151: ...7 1 Chapter 7 Troubleshooting...
Страница 154: ...7 4...
Страница 167: ...8 13 Panel cutout dimensions 4 M5 370 405 100 1 0 50 0 5 4 2 6 34 301 12 8 Specifications...
Страница 169: ...8 15 4 2 6 34 301 12 8 Specifications...
Страница 170: ...8 16...