background image

 

 

 

 

 

 

2015_03_03 

 

 

 

 

 

 

 

Installation and Operating Instructions    
 

 

 

Calculator with Ultrasonic Flow Sensor (Heat Meter, Cooling Energy Meter, Combined 
Heat/Cooling Energy Meter) 

microCLIMA ULTRA/SENSOSTAR®2C_US 

Certificate no:  
DE-09-MI004-PTB018 (MID heat); 22.72/09.01 (National German cooling) 

1

 

Application and Function 

Thermal  energy  meter  (heat  meter,  cooling  energy  meter  or  combined  heat/cooling  meter)  designed  for  the 
measurement of the consumed thermal energy in a closed heating or cooling or heating/cooling system.  

2

 

Scope of delivery 

-

 

Calculator with  ultrasonic flow  sensor (heat  meter, cooling  energy  meter,  combined  heat/cooling  energy 
meter) 

-

 

Installation kit: 5 self-lock seals + 5 seal-wires; O-ring ; 2  2 dowels for direct screw mounting  

-

 

2 gaskets for the flow sensor  

-

 

Installation and Operating Instructions 

3

 

General Information  

-

 

Valid  standards  for  the  application  of  heat  meters:  EN  1434,  parts  1  –  6;  the  Measuring  Instrument 
Directive 2004/22/EC, Annexes I and MI-004; and the relevant national verification regulations. 

-

 

For the selection, installation, commissioning, monitoring and maintenance of the instrument observe the 
standard EN 1434 part 6 as well as Annex 22 of the verification regulations (for Germany). 

-

 

National regulations for the consumption measurement of cooling must be observed. 

-

 

The technical regulations for electrical installations are to be observed. 

-

 

This  product  fulfils the  requirements  of the  European  Council Directive  on  Electromagnetic  Compatibility 
(EMC Directive) 2004/108/EC. 

-

 

The identification plate of the instrument and the seals must not be removed or damaged – otherwise the 
guarantee and the approved application of the instrument are no longer valid! 

-

 

To achieve measurement stability of the meter is it necessary that the water quality meet the requirements 
of the AGFW-recommendation FW-510 and the document VDI (Association of German Engineers) VDI 2035. 

-

 

The heat meter left the factory in conformance with all applicable safety regulations. All maintenance and 
repair work is to be carried out only by qualified and authorized technical personnel. 

-

 

The instrument must be stored and transported at temperatures above-freezing. 

-

 

Instruments with activated radio function are not allowed on air freight. 

-

 

The correct installation point in the system must be chosen: forward or return flow, as stated on the type 
identification label. 

-

 

The temperature sensor cables and the cable between the calculator and flow sensor must not be kinked, 
rolled up, lengthened or shortened. 

-

 

To clean the heat meter (only if necessary) use a slightly moist cloth. 

-

 

To protect against damage and dirt the meter should only be removed from the packaging directly before 
installation. 

-

 

If more than one meter is installed in one unit, care must be taken to ensure that all the meters have the 
same installation conditions. 

Содержание microCLIMA ULTRA

Страница 1: ...lations for electrical installations are to be observed This product fulfils the requirements of the European Council Directive on Electromagnetic Compatibility EMC Directive 2004 108 EC The identific...

Страница 2: ...be implemented at the installation site 4 2 General information on the ow sensor Be careful not to pick up the ow sensor on the plastic housing Always pick up and carry the sensor on the threaded or...

Страница 3: ...9 3 260 12 60 24 180 14 4 5 3 DN25 5 10 200 G 2 20 100 40 130 28 8 8 2 6 300 110 30 9 5 4 Mounting position Cooling meter See section 5 Installation for Cooling Applications Straight pipe sections Non...

Страница 4: ...g System Please inspect and check all dimensions to be sure that there is suf cient space in the intended location for installation of the ow sensor Flush the system thoroughly before installing the o...

Страница 5: ...w The calculator should be mounted on the wall for example Attention must be paid that the cables connected to the calcu lator are laid such that condensation water cannot run along them and into the...

Страница 6: ...lable which makes it possible for the wall mounting support to be mounted using standardized drill holes The centre to centre drill hole separation for the wall mounting unit and direct screw mounting...

Страница 7: ...on Slowly open the shut off valves Check that there are no leaks Check the following points Are all the shut off valves open Is the meter of the right size Is the heating heating cooling system clear...

Страница 8: ...dress factory setting is the serial number 10 Tariff register 1 Value alternating with tariff register no and criteria2 11 Tariff register 2 Values alternating with tariff register no and criteria2 12...

Страница 9: ...to 100 3 to 130 for temperature range 1 to 180 C Temperature difference cooling K 3 to 50 Calculation of heat from K 0 05 Calculation of cooling from K 0 05 Dual purpose heat cooling meter K HC 0 5 Re...

Страница 10: ...lustrations that apply depending on the interface Connection of M Bus Connection of pulse outputs or inputs Connection of pulse outputs heat cooling Connection of power pack Polarity is not important...

Страница 11: ...magnetic disturbances IEC 60364 5 51 2005 04 Electrical installations of buildings Part 5 51 Selection and erection of electrical equipment Common rules IEC 60364 5 54 2011 03 Low voltage electrical i...

Страница 12: ...tallation boxes substations they must be equipped with non metallic covers or doors The factory setting of the meters clock is standard winter Central European Time GMT 1 There is no automatic changeo...

Страница 13: ...on of the installation mode only compact telegrams will be transmitted 13 4 Two additional pulse inputs optional only in conjunction with M Bus or radio With this option additional instruments with pu...

Страница 14: ...h pulse without unit 1000 litres kWh pulse without unit Installation notes for pulse inputs It is important that the pulse cables are not be affected by or exposed to the M Bus voltage Check the polar...

Страница 15: ...onic switch according to EN 1434 2 2007 Pulse values See chapter 13 5 1 to 13 5 3 Peak switching current 300 mA Switching voltage maximum 35 V Switching power maximum 300 mW Contact isolation 109 Ohm...

Страница 16: ...ed circuited Rf sensor fault No calculations are carried out The registers for flow and energy are not being updated no new data is being stored Sensor cable severed sensor cable shorted circuited Int...

Страница 17: ...Directive 2004 108 EC on EMC Directive 2006 95 EC on low voltage Directive 1999 5 EC R TTE The complete signed declaration can be found at www engelmann de 16 Manufacturer Engelmann Sensor GmbH Rudolf...

Отзывы: