8 - 21
8 Communications Functions
Multi-function Compact Inverter 3G3MX2-V1 User’s Manual (I585-E1)
8-6
S
a
ving
a Chan
ge t
o
Ho
ldin
g R
egist
er (Ent
er Com
m
an
d)
8
8-6
-1 How
to Issue Ente
r Command
8-6
Saving a Change to Holding Register
(Enter Command)
The Write to Holding Register (06 hex) or Write to Consecutive Holding Registers (10 hex or 17 hex)
function is used to enable new register data. However, the new data is not stored in the EEPROM of the
inverter and is restored to the previous value when the inverter power supply is shut off.
To store a change to holding registers in the inverter’s EEPROM memory, issue the Enter command
according to the following procedure. In addition, after changing a control parameter, you need to recal-
culate the motor parameters. In this case, also use the Enter command to execute recalculation.
Use the Write to Holding Register (06 hex) command to write data to the holding register for the Enter
command (0900 hex). Below are the values to be written to the holding register (0900 hex).
*1. When the motor parameter initialization is executed, the parameters listed below are initialized to the default
data.
z
The list of parameters that are initialized by the motor parameter initialization
Precautions for Correct Use
• After receiving the Enter command, the inverter returns a response to the host and writes the
value to the EEPROM memory. You can monitor the during data write signal (Coil No. 0049
hex) to check whether the data is written.
• Since the inverter’s EEPROM memory has a limit for the number of rewrites (approximately
100,000 times), the inverter life may be shortened if the Enter command is frequently used.
8-6-1
How to Issue Enter Command
Set value
Description
0000
Motor parameter initialization
*1
0001
Set value storage
0002 to FFFF
Motor parameter initialization
*1
and set value storage
Parameter No.
Function name
A003/A203 Base
Frequency
A004/A204 Maximum
Frequency
A044/A244 Control
Method
A082/A282
Motor Rated Voltage Selection
b112
Free V/f Frequency 7
H002/H202 Motor
parameter selection
H003/H203 Motor
Capacity
H004/H204
Motor Pole Number
H005/H205 Speed
Response
H020/H220 to
H024/H224
Various motor parameters
Parameter No.
Function name
H030/H230 to
H034/H234
Various motor parameters
(Auto-tuning Data)
H102
PM Motor Parameter
Selection
H103
PM Motor Capacity
H104
PM Motor Pole Number
H105
PM Motor Rated Current
H106 to H110
Various PM motor parameters
H111 to H113
Various PM motor parameters
(Auto-tuning Data)
H116
PM Motor Speed Response
Содержание SYSDRIVE MX2 SERIES
Страница 1: ...Multi function Compact Inverter MX2 Series Type V1 User s Manual I585 E1 01 3G3MX2 A V1 ...
Страница 32: ...CONTENTS 29 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Страница 108: ...2 Design 2 48 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Страница 176: ...4 Parameter List 4 42 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Страница 310: ...6 Vector Control and Applied Functions 6 68 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Страница 516: ...9 Overview of DriveProgramming 9 4 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Страница 538: ...10 Troubleshooting 10 22 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Страница 598: ...12 Options 12 50 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Страница 614: ...Appendices A 16 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Страница 615: ...I 1 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 I Index ...