4 Parameter List
4 - 8
Multi-function Compact Inverter 3G3MX2-V1 User’s Manual (I585-E1)
*1. This setting is enabled when the Digital Operator with the volume control (Model: 3G3AX-OP01) is connected.
*2. The 3G3MX2-V1 Series Inverter does not provide the high-frequency mode.
Parameter
No.
Function name
Monitor or data range
Default
data
Set
data
Setting
during
RUN
Changes
during
RUN
Unit
Page
Mu
lti
-step
sp
eed,
jog
ging
A019
Multi-step Speed
Selection
00: Binary (16-step selection with
4 terminals)
00
Disabled Disabled
−
P. 5-49
01: Bit (8-step selection with 7 ter-
minals)
A020
1st Multi-step
Speed Reference 0
0.00
Starting Frequency to 1st Maximum
Frequency
6.00
Enabled
Enabled
Hz
A220
2nd Multi-step
Speed Reference 0
0.00
Starting Frequency to 2nd Maximum
Frequency
6.00
Enabled
Enabled
Hz
A021
Multi-step Speed
Reference 1
0.00
Starting Frequency to
Maximum Frequency
0.00
Enabled
Enabled
Hz
A022
Multi-step Speed
Reference 2
A023
Multi-step Speed
Reference 3
A024
Multi-step Speed
Reference 4
A025
Multi-step Speed
Reference 5
A026
Multi-step Speed
Reference 6
A027
Multi-step Speed
Reference 7
A028
Multi-step Speed
Reference 8
A029
Multi-step Speed
Reference 9
A030
Multi-step Speed
Reference 10
A031
Multi-step Speed
Reference 11
A032
Multi-step Speed
Reference 12
A033
Multi-step Speed
Reference 13
A034
Multi-step Speed
Reference 14
A035
Multi-step Speed
Reference 15
A038
Jogging Frequency Starting Frequency to 9.99
6.00
Enabled
Enabled
Hz
P. 5-52
A039
Jogging Stop
Selection
00: Free-running on jogging stop/
Disabled during operation
04
Disabled
Enabled
−
01: Deceleration stop on jogging
stop/Disabled during operation
02: DC injection braking on jogging
stop/Disabled during operation
03: Free-running on jogging stop/
Enabled during operation
04: Deceleration stop on jogging
stop/Enabled during operation
05: DC injection braking on jogging
stop/Enabled during operation
Содержание SYSDRIVE MX2 SERIES
Страница 1: ...Multi function Compact Inverter MX2 Series Type V1 User s Manual I585 E1 01 3G3MX2 A V1 ...
Страница 32: ...CONTENTS 29 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Страница 108: ...2 Design 2 48 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Страница 176: ...4 Parameter List 4 42 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Страница 310: ...6 Vector Control and Applied Functions 6 68 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Страница 516: ...9 Overview of DriveProgramming 9 4 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Страница 538: ...10 Troubleshooting 10 22 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Страница 598: ...12 Options 12 50 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Страница 614: ...Appendices A 16 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Страница 615: ...I 1 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 I Index ...