5 - 25
5 Basic Settings
Multi-function Compact Inverter 3G3MX2-V1 User’s Manual (I585-E1)
5-5
Frequ
ency
Referen
ce Sett
ing
s
5
5-
5-1 F
requen
cy Refer
ence Selection
Below are the details of the data of A001/A201.
*1. Refer to “DriveProgramming User’s Manual (I580)”.
*2. Refer to
7-5-7 Frequency Calculation Function
on page 7-39.
Precautions for Correct Use
The Output Frequency Setting/Monitor (F001) shows the frequency reference in the internal
memory (RAM).
F001 displays the frequency reference value selected at that time.
If you change the frequency reference value displayed in F001 and save it (by pressing the
Enter key), the data will be stored with the multi-step speed reference selected at that time.
• For the multi-step speed reference 0, the data will be stored with the 1st Multi-step Speed
Reference 0 (A020)/2nd Multi-step Speed Reference 0 (A220) according to the 1st/2nd Con-
trol Method selection.
• For the multi-step speed reference 1 to 15, the data will be stored with the corresponding
Multi-step Speed Reference 1 to 15 (A021 to A035).
Data
Frequency reference source
00
Sets the frequency reference via the volume control on the external Digital Operator
(Model: 3G3AX-OP01).
01
Sets the frequency reference via the control circuit terminal block (analog input signals).
(FV-SC, FI-SC)
02
Sets the frequency reference via the Digital Operator. (Output Frequency Setting/Monitor: F001)
03
Sets the frequency via Modbus communication.
04
Sets the frequency reference via the mounted communications option unit.
06
Sets the frequency reference based on the pulse train frequency input to the pulse input RP ter-
minal.
07
Sets the frequency reference via the DriveProgramming.
*1
10
Sets the calculation result of the frequency operation function as the frequency reference.
*2
* The frequency reference of Digital Operator (Volume), Control circuit terminal block (Analog
input), Modbus communication, Option, DriveProgramming, and Operation function output
cannot be changed in F001.
Содержание SYSDRIVE MX2 SERIES
Страница 1: ...Multi function Compact Inverter MX2 Series Type V1 User s Manual I585 E1 01 3G3MX2 A V1 ...
Страница 32: ...CONTENTS 29 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Страница 108: ...2 Design 2 48 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Страница 176: ...4 Parameter List 4 42 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Страница 310: ...6 Vector Control and Applied Functions 6 68 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Страница 516: ...9 Overview of DriveProgramming 9 4 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Страница 538: ...10 Troubleshooting 10 22 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Страница 598: ...12 Options 12 50 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Страница 614: ...Appendices A 16 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Страница 615: ...I 1 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 I Index ...