4 Parameter List
4 - 2
Multi-function Compact Inverter 3G3MX2-V1 User’s Manual (I585-E1)
4-1
Monitor Mode
The inverter by default displays the data of the parameter d001 after power-on. To monitor the desired
parameter at power-on, change this default setting in the Initial Screen Selection (b038).
The displayed parameters vary with the Display Selection (b037) setting. To display all parameters, set
this parameter to 00 (Complete display).
In the 3G3MX2-V1 Series, the default data for the Display Selection (b037) is 00 (Complete display), so
all parameters are displayed when you turn on the power supply for the first time after purchase.
The Monitor or data range column of the parameter list shows the range of parameters you can monitor
or set on the Digital Operator (4-digit LED display) of the inverter. For the actual internal data range for
this inverter, refer to
8-9 Modbus Communication Data Lists
on page 8-37.
To monitor or set detailed parameter data over the upper 4 digits, please use the Inverter/Servo support
tool CX-Drive.
*1. The 3G3MX2-V1 Series Inverter does not provide the high-frequency mode.
4-1-1
Group d
Parameter
No.
Function name
Monitor or data range
Default
data
Setting
during
RUN
Changes
during
RUN
Unit
Page
d001
Output Frequency
Monitor
0.00 to 99.99
100.0 to 400.0
*1
−
Enabled
Enabled
Hz
P. 7-4
d002
Output Current
Monitor
0.0 to 655.3
Minimal unit depends on inverter
capacity.
−
−
−
A
P. 7-4
d003
RUN Direction
Monitor
F: Forward
−
−
−
−
P. 7-5
o: Stop
r:
Reverse
d004
PID Feedback
Value Monitor
0.00 to 99.99
100.0 to 999.9
1000. to 9999.
1000 (10000)
−
−
−
−
P. 7-5
d005
Multi-function
Input Monitor
(Example)
Terminals S1, S2: ON
Terminals S3 to S7: OFF
−
−
−
−
P. 7-5
d006
Multi-function
Output Monitor
(Example)
Terminals P1, P2: ON
Terminal MA: OFF
−
−
−
−
P. 7-6
d007
Output Frequency
Monitor (After
Conversion)
0.00 to 99.99
100.0 to 999.9
1000. to 9999.
1000 to 4000
(10000 to 40000)
*1
−
Enabled Enabled
−
P. 7-6
ON
OFF
S7 S6 S5 S4 S3 S2 S1
ON
OFF
MA P2 P1
Содержание SYSDRIVE MX2 SERIES
Страница 1: ...Multi function Compact Inverter MX2 Series Type V1 User s Manual I585 E1 01 3G3MX2 A V1 ...
Страница 32: ...CONTENTS 29 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Страница 108: ...2 Design 2 48 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Страница 176: ...4 Parameter List 4 42 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Страница 310: ...6 Vector Control and Applied Functions 6 68 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Страница 516: ...9 Overview of DriveProgramming 9 4 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Страница 538: ...10 Troubleshooting 10 22 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Страница 598: ...12 Options 12 50 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Страница 614: ...Appendices A 16 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Страница 615: ...I 1 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 I Index ...