![Omron SYSDRIVE MX2 SERIES Скачать руководство пользователя страница 269](http://html.mh-extra.com/html/omron/sysdrive-mx2-series/sysdrive-mx2-series_user-manual_741918269.webp)
6 - 27
6 Vector Control and Applied Functions
Multi-function Compact Inverter 3G3MX2-V1 User’s Manual (I585-E1)
6-
6 Brake Co
nt
rol Fu
nct
ion
6
6-
6-2 Bra
ke C
ontrol Fun
ction Settings
Parameter
No.
Function name
Data
Default
data
Unit
b120
Brake Control Function
Selection
00: Disabled
00
−
01: Enabled (DC Injection Braking
enabled during stop)
02: Enabled (DC Injection Braking dis-
abled during stop)
b121
Brake Release Wait Time
0.00 to 5.00
The time from when the inverter reaches
the Brake Release Frequency until it out-
puts the brake release signal. Set the time
until the output current reaches the Brake
Release Current value.
0.00
s
b122
Acceleration Wait Time on
Brake Control
0.00 to 5.00
Set the mechanical delay time from when
the brake confirmation signal (or brake
release signal) turns ON until the brake is
activated actually.
0.00
s
b123
Stop Wait Time on Brake
Control
0.00 to 5.00
Set the mechanical delay time from when
the brake release signal turns OFF until
the brake is forced actually.
0.00
s
b124
Brake Error Detection Time
0.00 to 5.00
Set this to equal to or longer than the time
until the brake confirmation signal turns
ON after the brake release signal is
output.
0.00
s
b125
Brake Release Frequency
*1
*1. Set this to a value larger than the Starting Frequency (b082).
0.00 to 400.0
Set the frequency at which the brake
release signal is output.
0.00
Hz
b126
Brake Release Current
*2
*2. If the set value is too low, the inverter may not output a sufficient torque when the brake is released.
0.00 to 2.00
×
Rated current of inverter
Set an output current value sufficient
enough to support the load and output the
brake release signal.
Rated cur-
rent of
inverter
A
b127
Brake Force Frequency
*1
0.00 to 400.0
Set the frequency at which the brake
release signal turns OFF and forces the
brake during stop.
0.00
Hz
C001 to
C007
Multi-function Input S1 to S7
Selection
44: BOK (Brake confirmation)
−
−
C021,
C022
Multi-function Output P1/P2
Selection
−
−
19: BRK
(Brake
release)
C026
Multi-function Relay Output
(MA, MB) Function Selection
20: BER (Brake error)
Содержание SYSDRIVE MX2 SERIES
Страница 1: ...Multi function Compact Inverter MX2 Series Type V1 User s Manual I585 E1 01 3G3MX2 A V1 ...
Страница 32: ...CONTENTS 29 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Страница 108: ...2 Design 2 48 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Страница 176: ...4 Parameter List 4 42 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Страница 310: ...6 Vector Control and Applied Functions 6 68 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Страница 516: ...9 Overview of DriveProgramming 9 4 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Страница 538: ...10 Troubleshooting 10 22 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Страница 598: ...12 Options 12 50 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Страница 614: ...Appendices A 16 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Страница 615: ...I 1 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 I Index ...