![Omron SYSDRIVE MX2 SERIES Скачать руководство пользователя страница 155](http://html.mh-extra.com/html/omron/sysdrive-mx2-series/sysdrive-mx2-series_user-manual_741918155.webp)
4 - 21
4 Parameter List
Multi-function Compact Inverter 3G3MX2-V1 User’s Manual (I585-E1)
4-3 Ext
end
ed F
unc
tion
Mod
e
4
4-
3-2 Gro
up b: Det
a
iled Fun
ction Para
meters
*1. The 3G3MX2-V1 Series Inverter does not provide the high-frequency mode.
Parameter
No.
Function name
Monitor or data range
Default
data
Set
data
Setting
during
RUN
Changes
during
RUN
Unit
Page
Auxi
liary fu
ncti
on
b095
Regenerative
Braking Selection
00: Disabled (Function not active)
00
Disabled
Enabled
−
P. 5-65
01: Enabled (Disabled during stop)
02: Enabled (Enabled during opera-
tion and stop)
b096
Regenerative Brak-
ing ON Level
200-V class: 330. to 380.
360./
720.
Disabled
Enabled
V
400-V class: 660. to 760.
b097
Braking Resistor
Value
Minimum connection resistance to
600.0
Mini-
mum
resis-
tance
Disabled
Enabled
Ω
V/f
free
fun
ctio
n
b100
Free V/f
Frequency 1
0.: Disabled
0.
Disabled Disabled
Hz
P. 5-10
1. to Free V/f Frequency 2
b101
Free V/f Voltage 1
0.0 to 800.0
0.0
Disabled Disabled
V
b102
Free V/f
Frequency 2
0.: Disabled
0.
Disabled Disabled
Hz
Free V/f Frequency 1 to Free V/f Fre-
quency 3
b103
Free V/f Voltage 2
0.0 to 800.0
0.0
Disabled Disabled
V
b104
Free V/f
Frequency 3
0.: Disabled
0.
Disabled Disabled
Hz
Free V/f Frequency 2 to Free V/f Fre-
quency 4
b105
Free V/f Voltage 3
0.0 to 800.0
0.0
Disabled Disabled
V
b106
Free V/f
Frequency 4
0.: Disabled
0.
Disabled Disabled
Hz
Free V/f Frequency 3 to Free V/f Fre-
quency 5
b107
Free V/f Voltage 4
0.0 to 800.0
0.0
Disabled Disabled
V
b108
Free V/f
Frequency 5
0.: Disabled
0.
Disabled Disabled
Hz
Free V/f Frequency 4 to Free V/f Fre-
quency 6
b109
Free V/f Voltage 5
0.0 to 800.0
0.0
Disabled Disabled
V
b110
Free V/f
Frequency 6
0.: Disabled
0.
Disabled Disabled
Hz
Free V/f Frequency 5 to Free V/f Fre-
quency 7
b111
Free V/f Voltage 6
0.0 to 800.0
0.0
Disabled Disabled
V
b112
Free V/f
Frequency 7
0.: Disabled
0.
Disabled Disabled
Hz
Free V/f Frequency 6 to 400.
*1
b113
Free V/f Voltage 7
0.0 to 800.0
0.0
Disabled Disabled
V
Содержание SYSDRIVE MX2 SERIES
Страница 1: ...Multi function Compact Inverter MX2 Series Type V1 User s Manual I585 E1 01 3G3MX2 A V1 ...
Страница 32: ...CONTENTS 29 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Страница 108: ...2 Design 2 48 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Страница 176: ...4 Parameter List 4 42 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Страница 310: ...6 Vector Control and Applied Functions 6 68 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Страница 516: ...9 Overview of DriveProgramming 9 4 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Страница 538: ...10 Troubleshooting 10 22 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Страница 598: ...12 Options 12 50 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Страница 614: ...Appendices A 16 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Страница 615: ...I 1 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 I Index ...