![Omron SYSDRIVE MX2 SERIES Скачать руководство пользователя страница 170](http://html.mh-extra.com/html/omron/sysdrive-mx2-series/sysdrive-mx2-series_user-manual_741918170.webp)
4 Parameter List
4 - 36
Multi-function Compact Inverter 3G3MX2-V1 User’s Manual (I585-E1)
*1. The 3G3MX2-V1 Series Inverter does not provide the high-frequency mode.
*2. These parameters are newly added to the 3G3MX2-V1 Series.
Parameter
No.
Function name
Monitor or data range
Default
data
Set
data
Setting
during
RUN
Changes
during
RUN
Unit
Page
Co
mmun
ication
s o
pti
on
P044
Communications Error
Detection Timer Setting
0.00 to 99.99
1.00
Disabled Disabled
s
P. 7-101
P045
Operation Selection at
Host Communications
Error
00: Trip
00
Disabled Disabled
−
01: Trip after deceleration stop
02: Ignore
03: Free-run
stop
04: Deceleration
stop
P046
Assembly Instance
Number
0 to 20
1
Disabled Disabled
P048
Operation Selection at
Idle Mode Detection
00: Trip
00
Disabled Disabled
01: Trip after deceleration stop
02: Ignore
03: Free-run
stop
04: Deceleration
stop
P049
Number of Poles for
Rotation Speed Setting
0/2/4/6/8
10 to 48: Do not set.
0
Disabled Disabled
Pulse
train
in
put
P055
Pulse Train Frequency
Scale
1.0 to 32.0
25.0
Disabled
Enabled
kHz
P. 7-52
P056
Pulse Train Frequency
Filter Time Parameter
0.01 to 2.00
0.10
Disabled
Enabled
s
P057
Pulse Train Frequency
Bias Amount
−
100. to 100.
0.
Disabled
Enabled
%
P058
Pulse Train Frequency
Upper Limit
0. to 100.
100.
Disabled
Enabled
%
P059
Pulse Train Frequency
Lower Limit
*2
0.01 to 20.00
1.00
Disabled
Enabled
%
Simple position control
P060
Multi-step Position
Command 0
Position Limit Setting (Reverse Side)
(P073) to Position Limit Setting (For-
ward Side) (P072) (
×
1 multiplication)
(Displays upper 4digits including “
−
”)
0
Enabled
Enabled
pulse P. 6-45
P061
Multi-step Position
Command 1
0
Enabled
Enabled
P062
Multi-step Position
Command 2
0
Enabled
Enabled
P063
Multi-step Position
Command 3
0
Enabled
Enabled
P064
Multi-step Position
Command 4
0
Enabled
Enabled
P065
Multi-step Position
Command 5
0
Enabled
Enabled
P066
Multi-step Position
Command 6
0
Enabled
Enabled
P067
Multi-step Position
Command 7
0
Enabled
Enabled
P068
Origin Search Mode
00: Origin search mode 1
00
Enabled
Enabled
−
P. 6-40
01: Origin search mode 2
P069
Origin Search Direc-
tion Selection
00: Forward
side
01
Enabled
Enabled
−
01: Reverse
side
P070
Origin Search Mode 1
Frequency
0.00 to 10.00
*1
5.00
Enabled
Enabled
Hz
P071
Origin Search Mode 2
Frequency
0.00 to 1st Maximum Frequency
5.00
Enabled
Enabled
Hz
P072
Position Limit Setting
(Forward Side)
0 to 268435455
(Displays upper 4digits)
2684
35455
Enabled
Enabled
pulse
P. 6-34
P073
Position Limit Setting
(Reverse Side)
−
268435455 to 0
(Displays upper 4digits including “
−
”)
−
2684
35455
Enabled
Enabled
pulse
P075
Position Control Mode
Selection
00: Limit
00
Disabled Disabled
−
01: No
limit
Содержание SYSDRIVE MX2 SERIES
Страница 1: ...Multi function Compact Inverter MX2 Series Type V1 User s Manual I585 E1 01 3G3MX2 A V1 ...
Страница 32: ...CONTENTS 29 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Страница 108: ...2 Design 2 48 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Страница 176: ...4 Parameter List 4 42 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Страница 310: ...6 Vector Control and Applied Functions 6 68 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Страница 516: ...9 Overview of DriveProgramming 9 4 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Страница 538: ...10 Troubleshooting 10 22 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Страница 598: ...12 Options 12 50 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Страница 614: ...Appendices A 16 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Страница 615: ...I 1 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 I Index ...