![Omron SYSDRIVE MX2 SERIES Скачать руководство пользователя страница 166](http://html.mh-extra.com/html/omron/sysdrive-mx2-series/sysdrive-mx2-series_user-manual_741918166.webp)
4 Parameter List
4 - 32
Multi-function Compact Inverter 3G3MX2-V1 User’s Manual (I585-E1)
4-3-4
Group H: Motor Control Parameters
Parameter
No.
Function name
Monitor or data range
Default
data
Set
data
Setting
during
RUN
Changes
during
RUN
Unit
Page
Control p
aram
e
ter
s
H001
Auto-tuning Selection
00: Disabled
00
Disabled Disabled
−
P. 6-4
01: Enabled (No motor
rotation)
02: Enabled
(Motor
rota-
tion)
H002
1st Motor Parameter
selection
00: Standard
motor
para-
meter
00
Disabled Disabled
−
P. 6-4
H202
2nd Motor Parameter
Selection
02: Auto-tuning data
00
Disabled Disabled
H003
1st Motor Capacity
0.1/0.2/0.4/0.55/0.75/1.1/1.5/
2.2/3.0/3.7/4.0/5.5/7.5/11.0/
15.0/18.5
Maximum
applicable
motor
capacity
Disabled Disabled
kW
H203
2nd Motor Capacity
Disabled Disabled
kW
H004
1st Motor Pole Number
2/4/6/8
10 to 48: Do not set.
4
Disabled Disabled
pole
H204
2nd Motor Pole Num-
ber Selection
4
Disabled Disabled
H005
1st Speed Response
1. to 1000.
100.
Enabled
Enabled
−
H205
2nd Speed Response
100.
Enabled
Enabled
H006
1st Stabilization
Parameter
0. to 255.
100.
Enabled
Enabled
−
P. 7-52
H206
2nd Stabilization
Parameter
100.
Enabled
Enabled
H020
1st Motor Parameter
R1
0.001 to 9.999
10.00 to 65.53
Dependent
on capacity
Disabled Disabled
Ω
P. 6-9
H220
2nd Motor Parameter
R1
Dependent
on capacity
Disabled Disabled
H021
1st Motor Parameter
R2
0.001 to 9.999
10.00 to 65.53
Dependent
on capacity
Disabled Disabled
H221
2nd Motor Parameter
R2
Dependent
on capacity
Disabled Disabled
H022
1st Motor Parameter L
0.01 to 99.99
100.0 to 655.3
Dependent
on capacity
Disabled Disabled
mH
H222
2nd Motor Parameter L
Dependent
on capacity
Disabled Disabled
H023
1st Motor Parameter Io
0.01 to 99.99
100.0 to 655.3
Dependent
on capacity
Disabled Disabled
A
H223
2nd Motor Parameter
Io
Dependent
on capacity
Disabled Disabled
H024
1st Motor Parameter J
0.001 to 9.999
10.00 to 99.99
100.0 to 999.9
1000. to 9999.
Dependent
on capacity
Disabled Disabled
kgm
2
H224
2nd Motor Parameter J
Dependent
on capacity
Disabled Disabled
H030
1st Motor Parameter
R1
(Auto-tuning Data)
0.001 to 9.999
10.00 to 65.53
Dependent
on capacity
Disabled Disabled
Ω
P. 6-4
H230
2nd Motor Parameter
R1
(Auto-tuning Data)
Dependent
on capacity
Disabled Disabled
Ω
H031
1st Motor Parameter
R2
(Auto-tuning Data)
0.001 to 9.999
10.00 to 65.53
Dependent
on capacity
Disabled Disabled
Ω
H231
2nd Motor Parameter
R2
(Auto-tuning Data)
Dependent
on capacity
Disabled Disabled
Содержание SYSDRIVE MX2 SERIES
Страница 1: ...Multi function Compact Inverter MX2 Series Type V1 User s Manual I585 E1 01 3G3MX2 A V1 ...
Страница 32: ...CONTENTS 29 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Страница 108: ...2 Design 2 48 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Страница 176: ...4 Parameter List 4 42 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Страница 310: ...6 Vector Control and Applied Functions 6 68 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Страница 516: ...9 Overview of DriveProgramming 9 4 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Страница 538: ...10 Troubleshooting 10 22 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Страница 598: ...12 Options 12 50 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Страница 614: ...Appendices A 16 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 ...
Страница 615: ...I 1 Multi function Compact Inverter 3G3MX2 V1 User s Manual I585 E1 I Index ...