Control Period Read: RT
Section 3-12
3-12 Control Period Read: RT
Function
This command is used to read the control period that have been set at a con-
trol point.
The cooling
-
side control period that have been set at a control point can be
read provided that the E5ZE is a heating and cooling control model.
Command
Response
1.
The response block for Control Period Read (RT) does not include read
data if the end code of the response block is other than 00.
2.
Refer to
2-4 End Codes
.
Communications Example
In this example, the E5ZE is operated with Control Period Read (RT) under
the following conditions.
Unit no.:
1
Memory Bank no.: 2
Control Point:
3
Control Period:
5 s
Command
Response
@ R T
s
Terminator
FCS
x16
x16
Header code
*
Unit
Bank
Control
point
00: Control period
01: Cooling-side control period for
heating and cooling models only.
Data code
1
0
@ R T
s
Read data
Terminator
FCS
x16
x16
Header code
Control period
*
Unit
x10
x10
x10
x10
x16
x16
End code
1
1
1
0
0
0
3
2
*
@ 0 1 R T 2 3 0 0 4 6
s
Control period
*
@ 0 1 R T 0 0 0 0 0 5 4 2
s
5 s
Normal end