137
Initialize Setting Data: MC
Section 4-18
If the E5ZE is turned OFF before the E5ZE returns a response to Memory
Write (WE) to the host computer connected to the E5ZE, the setting data set
with the E5ZE may not be written to the memory, in which case a memory
error will occur.
Command
Response
Communications Example
In this example, setting data, the unit number of which has been set to 1, are
written to the memory with Memory Write (WE).
Command
Response
4-18 Initialize Setting Data: MC
Function
This command is used to set the memory to the factory
-
set default setting
data.
1.
Initialize Setting Data (MC) can be used only when the E5ZE is stopped.
2.
Initialize Setting Data (MC) cannot be used to reset a particular control
point or memory bank individually.
3.
Initialize Setting Data (MC) does not affect the contents of the memory and
saved calibration values. To initialize the stored set data of the E5ZE, send
this command and then Memory Write (WE) with the factory
-
set setting da-
ta.
If the temperature unit is changed from
°
C to
°
F or vice versa or the input type
connected to the E5ZE is changed at a control point, set the RAM to the fac-
tory
-
set default setting data and reset data with the E5ZE.
@ W E A A 0 0 0 0 0 7
s
Terminator
*
FCS
x16
x16
Unit
Setting data, always 0007
Header code
x10
x10
x10
x10
Data code
Always AA
1
1
0
0
3
2
@ W E
s
*
FCS
End code
Unit
x16
x16
x16
x16
Header code
Terminator
1
1
0
0
@ 0 1 W E A A 0 0 0 0 0 7 5 4
s
*
@ 0 1 W E 0 0 5 3
s
Normal end
*