Cooling Coefficient Read: RC
Section 6-4
Setting Data Range
If the cooling coefficient of a control point set to 0000 is used for temperature
control with the E5ZE, the percentage of the cooling
-
side control output will be
always 0.
Command
Response
Communications Example
In this example, the E5ZE is operated with Cooling Coefficient Write (WC)
under the following conditions.
Unit no.:
1
Memory Bank no.:
2
Control Point:
3
Cooling Coefficient: 1.5
Command
Response
6-4
Cooling Coefficient Read: RC
Function
This command is used to read the cooling coefficients that have been set at a
control point.
Command
Setting unit
0.1
Default
0010
Setting data
0000 to 0100
@ W C 0 0
s
Or minus
sign (-)
Decimal point
Control
point
Data code
Terminator
*
Cooling coefficient
FCS
x16
x16
Unit
Bank
Setting data
Header code
x10
x10
x10
x10
1
1
0
0
2
-1
@ W C
s
*
FCS
End code
Unit
x16
x16
x16
x16
Header code
Terminator
1
1
0
0
@ 0 1 W C 2 3 0 0 0 0 1 5 5 0
s
*
1.5
@ 0 1 W C 0 0 5 5
s
Normal end
*
@ R C 0 0
s
Control
point
Data code
Terminator
*
FCS
x16
x16
Unit
Bank
Header code
1
0