123
Setting Unit Read: Rt
Section 4-4
Response
4-4
Setting Unit Read: Rt
Function
This command is used to read the setting unit that has been set with the
E5ZE.
Command
Response
1.
The response block for Setting Unit Read (Rt) does not include read data
if the end code of the response block is other than 00.
2.
Refer to
2-4 End Codes
.
Communications Example
In this example, the E5ZE is operated with Setting Unit Read (Rt) under the
following conditions.
Unit no.: 1
Temperature Setting Unit: 1
Command
Response
@ 0 1 W t 0 0 6 2
s
Normal end
*
Always 00
@ R t 0 0 0 0
s
Header code
Terminator
*
Data code
FCS
Unit
x16
x16
1
0
@ R t
s
Read data
0000: Temperature setting unit is 1
0001: Temperature setting unit is 0.1
Terminator
FCS
x16
x16
Header code
Setting code
*
Unit
x10
x10
x10
x10
End code
x16
x16
1
1
1
0
0
0
3
2
@ 0 1 R t 0 0 0 0 6 7
s
*
@ 0 1 R t 0 0 0 0 0 0 6 7
s
*
Normal end
Temperature setting unit is 1