About this Manual:
This manual describes DeviceNet (CompoBus/D) and serial communications (using the RS
-
232C aux-
iliary setting jack) for E5ZE
-
8
@@@
D1
@
B
-
V2 Multipoint Temperature Controllers and includes the sec-
tions described below. DeviceNet communications are described in part 1 and serial communications
are described in part 2.
Please read this manual carefully and be sure you understand the information provided before
attempting to use DeviceNet communications with an E5ZE Multipoint Temperature Controller.
Read the following manuals before operating a E5ZE
-
8
@@@
D1
@
B
-
V2 Multipoint Temperature Control-
ler.
E5ZE Multipoint Temperature Controller Operation Manual (Cat. No. H076)
DeviceNet (CompoBus/D) Operation Manual (Cat. No. W267)
CS1W
-
DRM21 DeviceNet Unit Operation Manual (Cat. No. W380)
DeviceNet PCI Board Operation Manual (Cat. No. W381)
Part 1: DeviceNet Communications
Section 1
provides an overview of remote I/O and Explicit Messages that are supported by the E5ZE
for DeviceNet communications.
Section 2
provides details on installing the E5ZE in a DeviceNet Network and setting the DIP switch.
Section 3
provides details on remote I/O communications, including allocations in the PC, various
operating statuses, flags, and applications.
Section 4
provides details on DeviceNet explicit messages, including command and response for-
mats, the instructions used by the PC to execute DeviceNet explicit message communications, and
tables of set values and measurement values showing setting ranges, default values, data types, and
addresses.
Section 5
provides details on response end codes and indicators used to identify communications
errors.
Section 6
provides programming examples for both CV
-
series and C200HX/C200HE/C200HG PCs.
The Appendix provides details on multi
-
vendor applications.
Part 2: Serial Communications
Section 1
provides general information on serial communications and communications checks.
Section 2
provides a list of commands, end codes, and error codes. Information on writing and read-
ing data sets are also provided.
Section 3
describes the basic temperature control commands
Section 4
describes the commands that are used according to the application.
Section 5
describes the commands used for heater burnout and SSR failure detection.
Section 6
describes the commands used for heating and cooling control.
Section 7
describes the commands used for fuzzy control.
Section 8
describes the commands used for starting and stopping operation.
The Appendices provide communications programming examples and an ASCII code list.
!WARNING
Failure to read and understand the information provided in this manual may
result in personal injury or death, damage to the product, or product failure.
Please read each section in its entirety and be sure you understand the infor-
mation provided in the section and related sections before attempting any of
the procedures or operations given.