PC 101 Power Controller • Setup Guide
The Extron PC 101 Power Controller provides remote power management for AV devices. When paired with an Extron controller
or control processor with relays, such as the MediaLink MLC 226 IP or the IP Link IPL 250, the PC 101 can be set up to power an
AV device on or off at scheduled times. It has a contact closure control input for remote control of a device and a tally port that
can be used for status feedback. Its power rating of 100-240 VAC, 50-60 Hz, provides worldwide compatibility. A front panel test
switch enables manual power cycling for setup and test purposes. This guide provides instructions for an experienced installer to
set up and connect a PC 101.
NOTE:
For information on safety guidelines, regulatory compliances, EMI/EMF compatibility, accessibility, and related topics,
see the
Extron Safety and Regulatory Compliance Guide
at
www.extron.com
.
ATTENTION:
•
Use electrostatic discharge precautions (be electrically grounded) when making connections. Electrostatic discharge
(ESD) can damage equipment, although you may not feel, see, or hear it.
•
Prenez des précautions contre les décharges électrostatiques (soyez électriquement relié à la terre) lorsque vous
effectuez des connexions. Les décharges électrostatiques (ESD) peuvent endommager l’équipement, même si vous ne
pouvez pas le sentir, le voir ou l’entendre.
Rear Panel Features and Connections
F
F
E
E
D
D
C
C
B
B
A
A
TALLY
1 +V
CONTACT
IN
1 G
10A MAX
10A MAX
INPUT
OUTPUT
PC 101
TO
R
ESET
P
RE
SS
10
BREAKER
100-240 ~ 50-60Hz
100-240 ~ 50-60Hz
Figure 1.
PC 101 Rear Panel
A
Breaker
— 10 A rated circuit breaker. When an over
current condition occurs, the PC 101 stops outputting
AC current and ceases to function. Press this button
to manually reset the circuit breaker.
B
Input
— Power input
with a 6-inch IEC cable
attached. Connects AC power to the PC 101.
C
Output
— Power output with a 24-inch (60 cm) IEC
cable attached. Connects power to an output device.
D
Output power LED
— This green LED lights when
AC power is supplied to the Output connector. (The
front panel contains an output power LED which
performs the same function. Both LEDs reflect the
same status for the Output port.)
Make sure that the device being controlled can
support an AC power cycle.
E
Tally port
— 2-pole captive screw port
that toggles between high and low states.
An LED indicator can be connected to
this port to show when the connected
device is receiving power from the PC 101.
•
When the AC output is off, the tally
pin is in the high (floating) state.
•
When AC power is present on the
output, tally pin 1 toggles to the low
(grounded) state.
F
Contact In port
— 2-pole captive screw contact
closure input connector.
When pins 1 and G (ground) of this connector are
shorted together, the AC input passes power to the
output. If an LED is connected to the Tally port (
E
),
the LED lights when power is passed.
ATTENTION:
•
No greater than 10 A of current should pass through the unit.
•
Pas plus de 10 A de courant ne devrait passer au travers de l’unité.
TALLY
1
+V
+5 V