2 - 140
Memory Blocks
___________________________________________________________________________________
___________________________________________________________________________________
Document Revision 4
Electra Elite IPK
Display (R3000 or higher)
Notes
Programming Procedures
1
Go off-line.
2
Press LK1 + LK3 +
KC
to access the Memory Block.
3
Use the dial pad to enter the Data Setting for Class 1.
Setting Data
01s~99s (e.g., 05s =5s)
Default Values
10s
4
Press
G
to write the data and display the next memory block.
5
Program the next memory block, or press
E
to go back on-line.
Related Programming
M.B. Number
Memory Block Name
1-8-10
PBR Interdigit Release Time Selection
4-95
DTMF/DP SLT Type Selection
R3000 or higher is required to adjust this memory block by 1-second intervals.
0 3 : P B R
R L S
1 0 s
T I M E
D I S P L A Y
Setting
Data
Data
No.
Title