Electra Elite IPK
Document Revision 4
Programming Manual
2 - 401
___________________________________________________________________________________
___________________________________________________________________________________
1-16-11
Mirroring Source Port Assignment
General Description
When Port Mirroring is enabled in Memory Block 1-16-10 (Port Mirroring Selection),
use this Memory Block to specify a port with data to be monitored on another port
specified by Memory Block 1-16-12 (Mirroring Target Port Assigment) for each
HUB(8) -U( ) ETU. The source port and target port must be in the same VLAN(s).
R1500 or higher is required.
Display
Programming Procedures
1
Go off-line.
2
Press LK1 + LK16 +
JJAA
to access the Memory Block.
3
Use dial pad keys to enter Setting Data.
Use the following to enter data:
Use
J
to move cursor left
Use
L
to move cursor right
Use
K
~
I
to enter numeric data
Port range is 1~8.
Default Values:
Port 1
4
Press
G
to write the data.
5
Repeat steps 3 and 4 for each HUB(8)-U( ) ETU.
6
Press
E
to go back on-line.
System Mode
1
Submode
16
Data No.
11
PC Programming
¦
+AB
1 1 : 1
S O U R C E
= 1
T I M E
D I S P L A Y
Data
No.
Setting
Data
Title
HUB
1~3
Содержание ElectraElite IPK
Страница 2: ...PROGRAMMING MANUAL INT 1026 IPK Document Revision 4 Release 4000 4500 ...
Страница 3: ......
Страница 5: ......
Страница 802: ...PROGRAMMING MANUAL NEC Unified Solutions Inc Document Revision 4 Release 4000 4500 ...
Страница 803: ......