3 - 38
Advanced Applications
___________________________________________________________________________________
___________________________________________________________________________________
Document Revision 4
Electra Elite IPK
3.3.35
Call by Call ID Plan Assignment (Memory Block 1-10-01)
Use this Memory Block to specify Network ID Plan (NIP) for each
RAB as 0 (Reserved), 1 (Interexchange Carrier), 2 ~15 (Reserved).
The Network ID (Memory Block 1-10-04) must be assigned.
Default: 1 for all RABs
3.3.36
Call by Call Network ID Assignment (Memory Block 1-10-04)
Use this Memory Block to specify Network ID (NID) for each RAB.
Default: All RABs are unspecified
3.3.37
Call by Call Facility Coding Value Assignment (Service) (Memory
Block 1-10-05)
Use this Memory Block to specify Facility Coding Value (Service) for
each RAB as specified by the Memory Block table.
Default: All blocks 00 (None)
3.3.38
Call by Call Facility Coding Value Assignment (Feature) (Memory
Block 1-10-06)
Use this Memory Block to specify Facility Coding Value (Feature) for
each RAB as specified by the Memory Block table.
Default: All blocks 00 (None)
3.3.39
Call by Call Service Parameter Assignment (Memory Block1-10-07)
Use this Memory Block to specify Call Service Parameter for each
RAB as specified by the Memory Block table.
Default: All RABS 0-000
3.3.40
Call by Call Max Digit Assignment (Memory Block 1-10-08)
Use this Memory Block to specify Max Digit for each RAB.
Default: All RABs 00 (No Limit)