2 - 630
Memory Blocks
___________________________________________________________________________________
Document Revision 4
Electra Elite IPK
___________________________________________________________________________________
KSU Power-Based ETU Quantity Limitations
The following charts indicate the maximum number of specific ETU combinations in each KSU that are restricted by
power limitations of the KSU.
For System without EliteMail VP/CTI or CTI ETU loaded with Q-Master application
5
Press
G
to write the data.
6
Press
E
to go back on-line.
NO. of ESI(8)
ETUs
,
NO. of
ESI Ports
Either
EliteMail VP/CTI
Maximum NO. of
ACD+/CMS/FMS/VMP/
VMS/IPC/MG/IVR/IPT/
IAD/SLI/OPX/BSU(4M)/
BSU(2S)/BSU(6S) or
DID ETUs
Other ETUs
10
80
0
2
No Limitation
9
72
0
2
No Limitation
8
64
0
3
No Limitation
7
56
0
4
No Limitation
6
48
0
5
No Limitation
5
40
0
5
No Limitation
4
32
0
6
No Limitation
3
24
0
6
No Limitation
2
16
0
7
No Limitation
1
8
0
7
No Limitation
,
The number of 8-port ESI ETUs installed including ESI(8)-U( ), ESIB(8)-U( ), or ESIE(8)-U( ) ETU.
When the SPE(M)-U( ) ETU or the MIFM-U20 ETU (with Ethernet option installed) is installed in
the AP slot, the HUB(8)-U( ) ETU or Elite Mail CIT/VP must be installed in a different cabinet.
Only one CTI ETU can be installed in a KSU (EliteMail, VP, or Q-Master).