Electra Elite IPK
Document Revision 4
Programming Manual
2 - 23
___________________________________________________________________________________
___________________________________________________________________________________
1-1-14
CO Transfer Ring Tone Selection
General Description
Use this Memory Block to select a ring tone for CO transfers.
Display
Settings
LK 1
LK 2
LK 3
LK 4
LK 5
LK 6
LK 7
LK 8
The shaded
selection is the
default.
A
B
C
D
E
F
G
H
Programming Procedures
1
Go off-line.
2
Press LK1 +
LK1 +
AD
to access the Memory Block.
3
Press the corresponding CO/PBX line key to change the data option.
The available tones are:
4
Press
G
to write the data and display the next Memory Block.
5
Program the next Memory Block or press
E
to go back on-line.
Related Programming
M.B. Number
Memory Block Name
1-1-11
System Transfer/Camp-On Selection
1-1-13
CO Transfer Ring Pattern Selection
System Mode
1
Submode
1
Data No.
14
PC Programming
¦
+BCS
1 4 : C O T R F
T O N E
A
T I M E
D I S P L A Y
Title
Data
No.
Setting
Data
Tone
Frequency
Tone A
480/600 (Modulation - 16 Hz)
Tone B
480/606 (Modulation - 8 Hz)
Tone C
1024/1285
Tone D
1024
Tone E
500
Tone F
1024/1285 (Modulation - 16 Hz)
Tone G
600/700 (Modulation - 16 Hz)
Tone H
1024 (Envelope - 2 sec.)