2 - 20
Memory Blocks
___________________________________________________________________________________
___________________________________________________________________________________
Document Revision 4
Electra Elite IPK
Display (R3000 or higher)
Notes
Programming Procedures
1
Go off-line.
2
Press LK1 + LK1
+
AB
to access the Memory Block.
3
Use the dial pad to enter the Data Setting for Class 1.
Setting Data
000s~999s (e.g., 020s = 20s)
Default Values
Class 1~4 = 060s
000s = No Limit
4
Press
G
to write the data and display the next Timer Class of Service.
5
Program the next Timer Class of Service or press
E
to go back on-line.
Related Programming
M.B. Number
Memory Block Name
1-1-11
System Transfer/Camp-On Selection
1-6-01
Attendant Add-On Console to Telephone Port Assignment
1-8-08
Class of Service (Station) Feature Selection 2
4-71
Station to Timer Class of Service (R3000 or higher)
1.
Telephone ports 1 and 2 are in Station to Timer Class of Service, Class 1 by default. All other ports are in Station
to Timer Class of Service, Class 2 by default
(R3000 or higher)
.
2.
When a system is upgraded from R2500 or lower to
R3000 or higher,
the Station Transfer/Camp-On Recall
Time Selection is reset to the default during the upgrade process.
1 2 : T R F R C L
1 = 0 6 0 s
T I M E
D I S P L A Y
Timer
Class
1~4
Title
Data
No.
Setting
Data
Содержание ElectraElite IPK