2 - 88
Memory Blocks
___________________________________________________________________________________
___________________________________________________________________________________
Document Revision 4
Electra Elite IPK
1-1-68
8-Digit Matching Table to OCC Table
Assignment
General Description
Use this Memory Block to assign each 8-Digit Matching Table to each Other Common
Carrier (OCC) Code Table.
Display
Settings
Page 1
Related Programming
Refer to
Chapter 3 Advanced Applications
,
Section 1 Code Restriction on page 3-1
.
LK 1
LK 2
LK 3
LK 4
LK 5
LK 6
LK 7
LK 8
Default not
assigned.
Table 00
Table 01
Table 02
Table 03
Table 04
Table 05
Table 06
Table 07
Page 2
LK 1
LK 2
LK 3
LK 4
LK 5
LK 6
LK 7
LK 8
Table 08
Table 09
Table 10
Table11
Table 12
Table13
Table14
Table15
Programming Procedures
1
Go off-line.
2
Press LK1 +
LK1 +
FH
to access the Memory Block.
3
Press the corresponding CO/PBX line key to change data option.
Use the following to enter data:
C
to access the next page
A
to access the previous page
Each time a CO/PBX line key is pressed, the LED toggles between On
and Off.
Default Values
OCC Tables 01~15:
All Matching Tables Not Used
OCC Table 16:
Matching Tables 00~14 Not Used
Matching Table 15 Used
4
Press
G
to write the data and advance to the next OCC table. Repeat steps 3 and 4 until last OCC data is entered.
5
The next Memory Block is displayed.
6
Program the next Memory Block or press
E
to go back on-line.
System Mode
1
Submode
1
Data No.
68
PC Programming
¦
+AC
Data
No.
6 8 : 8 D G
O C C ( 0 1 ) | 1
T I M E
D I S P L A Y
OCC
Table
01~16
Title
Page No.
CO/PBX Line LED
Off
On
Data
Unused
Used
The shaded area
is the default
setting.