2 - 122
Memory Blocks
___________________________________________________________________________________
___________________________________________________________________________________
Document Revision 4
Electra Elite IPK
1-2-22
Call Forward - No Answer Time
Selection
General Description
Use this Memory Block to specify the time before incoming intercom calls or incoming
CO/PBX lines are forwarded to another station number when the called party does not
answer.
This Memory Block can be adjusted in 1-second intervals (R3000 or higher).
Display (R2500 or lower)
Settings
Refer to next page for R3000 or higher Programming Procedures.
LK 1
LK 2
LK 3
LK 4
LK 5
LK 6
LK 7
LK 8
The shaded
selection is the
default.
4s
8s
12s
18s
24s
30s
60s
Programming Procedures
1
Go off-line.
2
Press LK1 + LK2 +
BB
to access the Memory Block.
3
Press the corresponding CO/PBX line key to change the data option.
4
Press
G
to write the data and display the next Memory Block.
5
Program the next Memory Block or press
E
to go back on-line.
System Mode
1
Submode
2
Data No.
22
PC Programming
¦
+BM
2 2 : F W D
N O A N S
8 s
T I M E
D I S P L A Y
Setting
Data
Title
Data
No.
Содержание ElectraElite IPK
Страница 2: ...PROGRAMMING MANUAL INT 1026 IPK Document Revision 4 Release 4000 4500 ...
Страница 3: ......
Страница 5: ......
Страница 802: ...PROGRAMMING MANUAL NEC Unified Solutions Inc Document Revision 4 Release 4000 4500 ...
Страница 803: ......