Electra Elite IPK
Document Revision 4
Programming Manual
2 - 381
___________________________________________________________________________________
___________________________________________________________________________________
1-16-01 Port Speed Selection – 10/100 Base-T
General Description
When Memory Block 1-16-00 (Auto Negotiation Yes/No Selection) is set to NO, use
this Memory Block to specify the Ethernet port speed as 10 Mbps or 100 Mbps for
each port of each HUB(8)-U( ) ETU.
R1500 or higher is required.
Display
Settings
LK 1
LK 2
LK 3
LK 4
LK 5
LK 6
LK 7
LK 8
The shaded
selection is the
default.
10
100
Programming Procedures
1
Go off-line.
2
Press LK1 + LK16 +
JJKA
to access the Memory Block.
3
Press the corresponding CO/PBX line key to change the Setting Data option.
4
Press
G
to write the data.
5
Repeat steps 3 and 4 for each port.
6
Press
E
to go back on-line.
System Mode
1
Submode
16
Data No.
01
PC Programming
¦
+AB
0 1 : 1 - 1
S P E E D
1 0 0
T I M E
D I S P L A Y
Data
No.
Setting
Data
Title
PORT
1~8
HUB
1~3