PBX Line Ringing Pattern Selection
General Description
Use this Memory Block to assign the initial ringing pattern or no ring for incoming calls
on a PBX line.
Display
Page 1
Notes
LK 1
LK 2
LK 3
LK 4
LK 5
LK 6
LK 7
LK 8
The shaded
selection is the
default.
A
B
C
D
E
F
G
H
Page 2
LK 9
LK 10
LK 11
LK 12
LK 13
LK 14
LK 15
LK 16
NO
Programming Procedures
1
Go off-line.
2
Press LK1 + LK1 +
EB
to access the Memory Block.
3
Press corresponding CO/PBX line key to change data.
Use the following to enter data:
C
to access the next page
A
to access the previous page
4
Press
G
to write data and display the next Memory Block.
5
Program the next Memory Block or press
E
to go back on-line.
Do not program this Memory Block if Memory Block 1-1-59 (Synchronous Ringing Selection) is assigned YS.
System Mode
1
Submode
1
Data No.
52
PC Programming
¦
+BCS
5 2 : P B X
P T N
B | 1
T I M E
D I S P L A Y
Title
Data
No.
Setting
Data
Page
No.