1-10-07 Call by Call Service Parameter
Assignment
General Description
Use this Memory Block to specify the Service Parameters for each Route Advance
Block (RAB). This setting data is sent to the Service Parameters in the NSF-IE
(Network Specific Facility Code-Information Element) when making outgoing calls.
Service Parameter Assignment is an Identification Number that is assigned when
subscribing with the carrier for the different services.
Display
Programming Procedures
1
Go off-line.
2
Press LK1 + LK10 +
JG
to access the Memory Block.
3 Enter 1~5 digits for Setting Data using the dial pad.
Use the following to enter data:
J
and
L
to move the cursor
K
~
I
to enter data
D
to select next RAB No.
Setting Data No. 1 = 0 or 1 for each entry.
Setting Data No. 2 = Three-digit code 000~127 for each entry.
Default Values
All RABs 0~000
4
Press
G
to write the data. Digit 2 is displayed.
5
Repeat Steps 3 and 4 for each remaining digit for RAB 1. The next Memory Block is displayed.
6
Program the next Memory Block or press
E
to go back on-line.
System Mode
1
Submode
10
Data No.
07
PC Programming
¦
+AY
0 1 / 0 7 : S P
1 = 0 – 0 0 0
T I M E
D I S P L A Y
Data
No.
Setting
Data 2
RAB
01~32
Title
Setting
Data 1
1~5