2 - 106
Memory Blocks
___________________________________________________________________________________
___________________________________________________________________________________
Document Revision 4
Electra Elite IPK
Display (R3000 or higher)
Notes
Programming Procedures
1
Go off-line.
2
Press LK1 + LK2
to access the Memory Block.
3
Use the dial pad to enter the Data Setting for Class 1.
Setting Data
000s~255s (e.g., 020s = 20s)
Default Values
Class 1~4 = 090s
000s = No Limit
4
Press
G
to write the data and display the next Timer Class of Service.
5
Program the next Timer Class of Service or press
E
to go back on-line.
Related Programming
M.B. Number
Memory Block Name
1-7-06
External Paging Timeout Selection
4-93
Internal Zone Paging Selection
4-71
Station to Timer Class of Service (R3000 or higher)
1.
Types of paging include:
H
All Internal Zone (51)
H
Internal Zone Paging (52~54)
H
External Zone Paging (all speakers) (55)
H
External Zone Paging (individual speakers) (56~58)
H
Internal/External Zone Paging (59)
2.
Telephone Ports 1 and 2 are in Station to Timer Class of Service, Class 1, by default. All other ports are in
Station to Timer Class of Service, Class 2, by default.
3.
When a system is upgraded from R2500 or lower to R3000 or higher, the Internal Paging Timeout Selection is
reset to the default during the upgrade process.
0 0 : P A G I N G
1 = 0 9 0 s
T I M E
D I S P L A Y
Timer
Class
1~4
Title
Data
No.
Setting
Data