1-16-12 Mirroring Target Port Assignment
General Description
When Port Mirroring is enabled in Memory Block 1-16-10 (Port Mirroring Selection),
use this Memory Block to specify a target port that monitors frames transmitted on the
source port specified by Memory Block 1-16-11 (Mirroring Source Port Assigment) for
each HUB(8)-U( ) ETU. The source port and target port must be in the same VLAN(s).
R1500 or higher is required.
Display
Programming Procedures
1
Go off-line.
2
Press LK1 + LK16 +
JJAB
to access the Memory Block.
3
Use dial pad keys to enter Setting data.
Use the following to enter data:
Use
J
to move cursor left
Use
L
to move cursor right
Use
K
~
I
to enter numeric data
Port range is 1~8.
Default Values:
Port 1
4
Press
G
to write the data.
5
Repeat steps 3 and 4 for each HUB(8)-U( ) ETU.
6
Press
E
to go back on-line.
System Mode
1
Submode
16
Data No.
12
PC Programming
¦
+AB
1 2 : 1
T A R G E T
= 1
T I M E
D I S P L A Y
Data
No.
Setting
Data
Title
HUB
1~3
Содержание ElectraElite IPK