3 - 16
Advanced Applications
___________________________________________________________________________________
___________________________________________________________________________________
Document Revision 4
Electra Elite IPK
2.3
Memory Block Description
2.3.1
Access Code (1-Digit) Assignment (Memory Block 1-1-46)
Use this Memory Block to assign Trunk Group Access code for LCR.
Default: Dial 9 Function number 101
2.3.2
Class of Service (Station) Feature Selection 2 (Memory Block
1-8-08)
Use this Memory Block to allow/deny LCR Bypass (Page 3, LK4) for
Trunk Groups 02~32).
Default: Deny
Use this Memory Block to allow/deny ARS Overflow (Page 6, LK1) to
trunk group 01 when programmed route is busy.
Default: Deny
2.3.3
ARS Allow/Deny Selection (Memory Block 1-14-00)
Use this Memory Block to specify whether or not to Allow ARS to
function system wide.
Default: NO
2.3.4
ARS Dialing Assignment (Memory Block 1-14-01)
Use this Memory Block to assign a dialing plan to one of four LCR
tables. A maximum of 128 (up to 8 digits) dialing combinations are
possible for each table.
Default: Not Assigned
2.3.5
ARS Dial Allow/Deny Selection (Memory Block 1-14-02)
Use this Memory Block to specify whether or not to Allow digits that
are entered in the ARS dialing assignment to be routed using the
ARS feature.
Default: YES
2.3.6
ARS Route Table Number Assignment (Memory Block 1-14-03)
Use this Memory Block to assign each ARS Dialing Assignment to
an ARS Route Assignment (01~32).
Default: 00 (Not used)
2.3.7
ARS Trunk Group to Route Number Assignment (Memory Block
1-14-04)
Use this Memory Block to specify whether a Trunk Group (TKGP) or
Route Advance Group (RAB) is used by each ARS route number.