2 - 148
Memory Blocks
___________________________________________________________________________________
___________________________________________________________________________________
Document Revision 4
Electra Elite IPK
1-3-11
SLT/PS II Talk Start Timer
General Description
Use this Memory Block to assign the time needed after a hookflash and dialing before
three-party (two COs and one SLT) line conference is allowed from a Single Line
Telephone or PSII.
System Software R2000 or higher is required.
Display
Programming Procedures
1
Go off-line.
2
Press LK1 + LK3 +
AA
to access the Memory Block.
3
Use the dial pad to enter data.
Use the following to enter data:
K
~
I
to enter numeric data
J
to move the cursor left
L
to move the cursor right
Setting Data: 01~99 sec
Default Values
10 sec
4
Press
G
to write the data and display the next Memory Block.
5
Program the next Memory Block or press
E
to go back on-line.
Related Programming
M.B. Number
Memory Block Name
1-8-08
Class of Service (Station) Feature Selection 2
Page 3, LK 5
3-04
Trunk-to-Trunk Transfer Yes/NO Selection
4-17
Station to Class of Service Feature Assignment
System Mode
1
Submode
3
Data No.
11
PC Programming
¦
+BTI
1 1 : T L K
T M R
= 1 0 s
T I M E
D I S P L A Y
Data
No.
Title
Setting
Data