1-10-06 Call by Call Facility Coding Value
Assignment (Feature)
General Description
Use this Memory Block to specify the Facility Coding Value (Feature) for each Route
Advance Block (RAB). This setting data is sent in the FCV-F field of the NSF-IE
(Network Specific Facility Code-Information Element) when making outgoing calls.
Display
Programming Procedures
1
Go off-line.
2
Press LK1 + LK10 +
JF
to access the Memory Block.
3 Enter three or four digit data using the dial pad.
Use the following to enter data:
J
and
L
to move the cursor
K
~
I
to enter data
D
to select next RAB No.
Setting Data:
Default Values
All RABs 00
4
Press
G
to write the data. The next Memory Block is displayed.
5
Program the next Memory Block or press
E
to go back on-line.
System Mode
1
Submode
10
Data No.
06
PC Programming
¦
+AY
0 1 / 0 6 : F C V – F
=
0 0
T I M E
D I S P L A Y
Data
No.
Setting
Data
Rab
01~32
Title
PRT ETU SW1
Setting
Setting Data
Description
5ESS (AT&T)
00
Non-CBC Route Advance Block (None)
01~04
Reserved (Not Used)
05
Operator (Local Exchange)
06
Operator (Default-Common Carrier)
07~31
Reserved (Not Used)