2 - 248
Memory Blocks
___________________________________________________________________________________
___________________________________________________________________________________
Document Revision 4
Electra Elite IPK
1-8-40
ACD Hunt Time
General Description
Use this Memory Block to assign the time for hunting among the Automatic Call
Distribution/Uniform Call Distribution (ACD/UCD) agents that do not answer an ACD/
UCD call.
Display
Settings
LK 1
LK 2
LK 3
LK 4
LK 5
LK 6
LK 7
LK 8
The shaded
selection is the
default.
10s
20s
30s
60s
120s
240s
∞
(No Limit)
Programming Procedures
1
Go off-line.
2
Press LK1 + LK8 +
DK
to access the Memory Block.
3
Press the corresponding CO/PBX line key to assign the value.
Default Values
10 seconds
4
Press
G
to write the data. The next Memory Block is displayed.
5
Program next Memory Block or press
E
to go back on-line.
Related Programming
M.B. Number
Memory Block Name
1-8-25
ACD/UCD Group Agent Assignment
1-12-00
ACD/UCD Group Pilot Number Assignment
1-12-01
ACD/UCD Group Overflow Destination Assignment
1-12-02
ACD/UCD Overflow Time Selection
System Mode
1
Submode
8
Data No.
40
PC Programming
¦
+AA
4 0 : A C D
T I M E R
1 0 S
T I M E
D I S P L A Y
Data
No.
Setting
Data